HDD 3.5" SCSI HP COMPAQ 146Gb 15K

Размещено 05.12.2016 в 10:50

Цена Параметры Детали
800 ₽

Комплектация:
HDD COMPAQ BF1468A4B3
Салазки HP Spare 404712-001

Тест поверхности: Victoria 4.47
Сектор начала тестирования: 0
Сектор конца тестирования: 286 734 239
Протестировано от общего объема в %: 100
BAD-сектора: 0
см. скриншот результатов проверки

--------- ADUReaport.txt ---------
********* Блок заголовка файла *********
ACU Version 9.40.12.0
Diagnostic Module Version 6.2.25.0
INFOMGR Version 6.1.29.0
Time Generated Monday December 05, 2016 11:23:14AM
********* Блок о HDD *********
Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:2 : Physical Drive Status

SCSI Bus 1 (0x01)
SCSIID 2 (0x02)
Block Size 512 Bytes Per Block (0x0200)
Total Blocks 146.8 GB (0x11175330)
Reserved Blocks 0x00000440
Drive Model COMPAQ BF1468A4B3
Drive Serial Number JAW5RH5K
Drive Firmware Revision HPB8
SCSI Inquiry Bits 0x3a
Compaq Drive Stamped Stamped For Monitoring (0x01)
Last Failure Reason Timeout (0x07)
Device Flags 0xcd
Position Device Flag Status
-------- ----------------------------- -------------
0 Drive Present And Operational Informational
2 Wide SCSI Transfers Enabled Informational
3 Synchronous Transfers Enabled Informational
6 Ultra SCSI Transfers Enabled Informational
7 Ultra2 SCSI Transfers Enabled Informational

More Device Flags 0x25
Position Device Flag Status
-------- ------------------------------------- -------------
0 SMART Predictive Failure Supported Informational
2 SMART Predictive Failure Is Enabled Informational
4 Device Attached To Internal Connector Informational
5 Configured Data Drive Informational

SCSI Lun 0x00
Yet More Device Flags 0x9d
Position Device Flag Status
-------- --------------------------------------- -------------
0 DT Clocking Mode Informational
2 DT And ST Clocking Supported Informational
3 U320 Transfers Enabled Informational
4 Supports Packetized SCSI Informational
7 Drive Write Cache Setting Is Changeable Informational

Even More Device Flags 0x05
Position Device Flag Status
-------- ------------------------- -------------
0 QAS Is Supported Informational
2 SCSI Arbitration Fairness Informational

Spi Speed Rules 0xf8b70800
Physical Port J2
Physical Box 0 (0x00)
Physical Bay 2 (0x02)
RPM 15000 RPM (0x00003a98)
Device Type Parallel (0x00)
SATA Version 0x00
Big Total Block Count 0x0000000000000000
RIS Starting LBA 0x0000000000000000
RIS Size 0 MB (0x00000000)
WWID All Zeroes (20 x [0x00])
Controller PHY Map All Zeroes (32 x [0x00])
PHY Count 0 (0x0000)
PHY Connected Device Type All Zeroes (256 x [0x00])
PHY To Drive Bay Number All Zeroes (256 x [0x00])
PHY To Attached Device Index All Zeroes (256 x [0x0000])
Box Index 0 (0x00)
MSA Support 0x00
Extra Device Flags 0x0000
Negotiated Link Rate All Zeroes (256 x [0x00])
Phy To Phy Map All Zeroes (256 x [0x00])
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Multi LUN Device LUN Count 0x00
Minimum Good Firmware Revision empty
Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00])
Current Temperature 0x00
Temperature Threshold 0x00
Maximum Temperature 0x00
Logical Blocks Per Physical Block 0x00
Current Q Depth Limit 0x0000
Switch Name All Zeroes (10 x [0x00])
Switch Port 0x0000
Alternate Paths Switch Name All Zeroes (40 x [0x00])
Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Power On Hours 0x0000
Percent Endurance Used 0x0000
Drive Authentication 0x00
Smart Carrier Authentication 0x00
Smart Carrier Application Version 0x00
Smart Carrier Bootloader Version 0x00
Sanititze Erase Support 0x00
Encryption Flags 0x00
Encryption Key Name empty

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:2 : Monitor and Performance Statistics (Since Factory)

Serial Number JAW5RH5K
Firmware Revision HPB5
Product Revision COMPAQ BF1468A4B3
Reference Time 0x00300b3f
Sectors Read 0x0000004ab53c3a10
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x0000000255a545fe
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000002
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 1 (0x0001)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 1 (0x00000001)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:2 : Monitor and Performance Statistics (Since Reset)

Serial Number JAW5RH5K
Firmware Revision HPB8
Product Revision COMPAQ BF1468A4B3
Reference Time 0x00000056
Sectors Read 0x0000000011173d23
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x0000000000000851
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:2 : Monitor and Performance Violations

Threshold Violation Flags All Zeroes (256 x [0x00])
Offset To Extended Threshold Violation Flags 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
Total Structure Length 0 (0x00000000)
Fixed Structure Length 0 (0x00000000)

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:2 : Monitor and Performance Parameter Control

Serial Number 0x8054
Firmware Revision 0x8248
Product Revision 0x8268
Reference Time 0x8184
Sectors Read 0x8108
Read Errors Hard 0x8184
Read Errors Retry Recovered 0x8184
Read Errors ECC Corrected 0x8188
Sectors Written 0x8108
Write Errors Hard 0x8184
Write Errors Retry Recovered 0x8184
Seek Count 33032 (0x8108)
Seek Errors 0x8188
Spin Cycles 0x8184
Spin Up Time 0x8a82
Performance Test 1 0x0a82
Performance Test 2 0x8a82
Performance Test 3 0x8a82
Performance Test 4 0x8a82
Reallocation Sects 0x0a04
Reallocated Sects 0x8d84
DRQ Timeouts 0x0982
Other Timeouts 0x0182
Drive Rebuild Count 386 (0x0182)
Spin Retries 2434 (0x0982)
Recovers Failed Read 0x8182
Recovers Failed Write 0x0182
Format Errors 0x0182
Self Test Failures 0x0982
Not Ready Failures 0x0184
Remap Abort Failures 0x0984
IRQ Deglitch Count 0x0984
Bus Faults 33156 (0x8184)
Hot Plug Count 0x0184
Track Rewrite Errors 0x0982
Write Errors After Remap 0x0982
Background Firmware Revision 0x0a48
Media Failures 0x0182
Hardware Errors 0x0182
Aborted Command Failures 0x0182
Spin Up Failures 0x0182
Bad Target Count 386 (0x0182)
Predictive Failure Errors 0x2184

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:2 : Parallel Scsi Physical Drive Error Log

Entry Size 20 (0x14)
Entry Count 20 (0x0014)
Next Entry Offset 0x01
Errors Logged 1 (0x00000001)
Physical Drive Error Log Entries Error Type SCSI Operation Code SCSI Status CAM Status Sense Key ASC ASCQ Block Valid Block Reference Time Additional Information
---------- ------------------- ----------- ---------- --------- ---- ---- ----------- ---------- -------------- ----------------------
0x01 0x00 0x02 0x04 0x06 0x29 0x03 0x00 0x00000000 0x00151a6d 0x0000

Reference Time 0x00300b3f

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:2 : Mode Sense 10

Header 0x00 0xde 0x00 0x10 0x00 0x00 0x00 0x08 0x00 0x00 0x00 0x00 0x00 0x00 0x02 0x00
Mode Page Page Number Page Data
----------- -----------------------------------------------------------------------------------------------------------------------
0x00 0x80 0x0e 0x00 0xa1 0x00 0x12 0x00 0x00 0x40 0x4b 0x00 0x3c 0x10 0x20 0x00 0x20
0x01 0x81 0x0a 0xe4 0x01 0x00 0x00 0x00 0x00 0x01 0x00 0x00 0x00
0x02 0x82 0x0e 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x70 0x00 0x00 0x00
0x03 0x03 0x16 0x13 0x5f 0x00 0x00 0x00 0x00 0x00 0x00 0x03 0x48 0x02 0x00 0x00 0x01 0x00 0x00 0x00 0x28 0x40 0x00 0x00 0x00
0x04 0x04 0x16 0x00 0xa4 0x07 0x0a 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x3a 0x98 0x00 0x00
0x07 0x87 0x0a 0x04 0x01 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x08 0x88 0x12 0x00 0x00 0xff 0xff 0x00 0x00 0xff 0xff 0xff 0xff 0x00 0x0e 0x00 0x00 0x00 0x00 0x00 0x00
0x09 0x89 0x0e 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x04 0x00
0x0a 0x8a 0x0a 0x00 0x10 0x00 0x00 0x00 0x00 0x00 0x00 0x09 0x6b
0x0c 0x8c 0x16 0x80 0x00 0x00 0x18 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0xa4 0x5a 0x09 0x00 0x00 0x00 0x00 0x00 0x00 0x10 0x0c
0x19 0x99 0x06 0x01 0x00 0x00 0x00 0x00 0x00
0x1a 0x9a 0x0a 0x00 0x00 0xff 0xff 0xff 0xff 0xff 0xff 0xff 0xff
0x1c 0x9c 0x0a 0x11 0x04 0x00 0x00 0x0b 0xb8 0x00 0x00 0x00 0x02

800 ₽
800 ₽
BF1468A4B3, no warnings, no errors

Комплектация:
HDD HP BF1468A4CC
Салазки HP Spare 404712-001

Тест поверхности:
Сектор начала тестирования: 0
Сектор конца тестирования: 286 734 239
Протестировано от общего объема в %: 100
Результаты сканирования: no warnings, no errors
Подробнее смотри скриншот результатов проверки Victoria 4.47

--------- ADUReaport.txt ---------
Time Generated: Thursday December 08, 2016 12:07:50PM


Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Physical Drive Status

SCSI Bus 0 (0x00)
SCSIID 5 (0x05)
Block Size 512 Bytes Per Block (0x0200)
Total Blocks 146.8 GB (0x11175330)
Reserved Blocks 0x00000440
Drive Model COMPAQ BF1468A4CC
Drive Serial Number 3KN28RD000009709PX47
Drive Firmware Revision HPB5
SCSI Inquiry Bits 0x3e
Compaq Drive Stamped Stamped For Monitoring (0x01)
Last Failure Reason No Failure (0x00)
Device Flags 0xcd
Position Device Flag Status
-------- ----------------------------- -------------
0 Drive Present And Operational Informational
2 Wide SCSI Transfers Enabled Informational
3 Synchronous Transfers Enabled Informational
6 Ultra SCSI Transfers Enabled Informational
7 Ultra2 SCSI Transfers Enabled Informational

More Device Flags 0x25
Position Device Flag Status
-------- ------------------------------------- -------------
0 SMART Predictive Failure Supported Informational
2 SMART Predictive Failure Is Enabled Informational
4 Device Attached To Internal Connector Informational
5 Configured Data Drive Informational

SCSI Lun 0x00
Yet More Device Flags 0x9d
Position Device Flag Status
-------- --------------------------------------- -------------
0 DT Clocking Mode Informational
2 DT And ST Clocking Supported Informational
3 U320 Transfers Enabled Informational
4 Supports Packetized SCSI Informational
7 Drive Write Cache Setting Is Changeable Informational

Even More Device Flags 0x05
Position Device Flag Status
-------- ------------------------- -------------
0 QAS Is Supported Informational
2 SCSI Arbitration Fairness Informational

Spi Speed Rules 0xf8b70800
Physical Port J1
Physical Box 0 (0x00)
Physical Bay 5 (0x05)
RPM 15000 RPM (0x00003aa7)
Device Type Parallel (0x00)
SATA Version 0x00
Big Total Block Count 0x0000000000000000
RIS Starting LBA 0x0000000000000000
RIS Size 0 MB (0x00000000)
WWID All Zeroes (20 x [0x00])
Controller PHY Map All Zeroes (32 x [0x00])
PHY Count 0 (0x0000)
PHY Connected Device Type All Zeroes (256 x [0x00])
PHY To Drive Bay Number All Zeroes (256 x [0x00])
PHY To Attached Device Index All Zeroes (256 x [0x0000])
Box Index 0 (0x00)
MSA Support 0x00
Extra Device Flags 0x0000
Negotiated Link Rate All Zeroes (256 x [0x00])
Phy To Phy Map All Zeroes (256 x [0x00])
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Multi LUN Device LUN Count 0x00
Minimum Good Firmware Revision empty
Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00])
Current Temperature 0x00
Temperature Threshold 0x00
Maximum Temperature 0x00
Logical Blocks Per Physical Block 0x00
Current Q Depth Limit 0x0000
Switch Name All Zeroes (10 x [0x00])
Switch Port 0x0000
Alternate Paths Switch Name All Zeroes (40 x [0x00])
Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Power On Hours 0x0000
Percent Endurance Used 0x0000
Drive Authentication 0x00
Smart Carrier Authentication 0x00
Smart Carrier Application Version 0x00
Smart Carrier Bootloader Version 0x00

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Factory)

Serial Number 3KN28RD000009709PX47
Firmware Revision HPB5
Product Revision COMPAQ BF1468A4CC
Reference Time 0x0033eedf
Sectors Read 0x00000039d9994309
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x000000000000000a
Sectors Written 0x000000115eaf752d
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Reset)

Serial Number 3KN28RD000009709PX47
Firmware Revision HPB5
Product Revision COMPAQ BF1468A4CC
Reference Time 0x0000005c
Sectors Read 0x0000000012028032
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x00000000000001fc
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0x0099
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Violations

Threshold Violation Flags All Zeroes (256 x [0x00])
Offset To Extended Threshold Violation Flags 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
Total Structure Length 0 (0x00000000)
Fixed Structure Length 0 (0x00000000)

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Parameter Control

Serial Number 0x8054
Firmware Revision 0x8248
Product Revision 0x8268
Reference Time 0x8184
Sectors Read 0x8108
Read Errors Hard 0x8184
Read Errors Retry Recovered 0x8184
Read Errors ECC Corrected 0x8188
Sectors Written 0x8108
Write Errors Hard 0x8184
Write Errors Retry Recovered 0x8184
Seek Count 33032 (0x8108)
Seek Errors 0x8188
Spin Cycles 0x8184
Spin Up Time 0x8a82
Performance Test 1 0x0a82
Performance Test 2 0x8a82
Performance Test 3 0x8a82
Performance Test 4 0x8a82
Reallocation Sects 0x0a04
Reallocated Sects 0x8d84
DRQ Timeouts 0x0982
Other Timeouts 0x0182
Drive Rebuild Count 386 (0x0182)
Spin Retries 2434 (0x0982)
Recovers Failed Read 0x8182
Recovers Failed Write 0x0182
Format Errors 0x0182
Self Test Failures 0x0982
Not Ready Failures 0x0184
Remap Abort Failures 0x0984
IRQ Deglitch Count 0x0984
Bus Faults 33156 (0x8184)
Hot Plug Count 0x0184
Track Rewrite Errors 0x0982
Write Errors After Remap 0x0982
Background Firmware Revision 0x0a48
Media Failures 0x0182
Hardware Errors 0x0182
Aborted Command Failures 0x0182
Spin Up Failures 0x0182
Bad Target Count 386 (0x0182)
Predictive Failure Errors 0x2184

800 ₽
800 ₽
BF1468A4CC, no warnings, no errors

Комплектация:
HDD HP BF1468A4CC
Салазки HP Spare 404712-001

Тест поверхности:
Сектор начала тестирования: 0
Сектор конца тестирования: 286 734 239
Протестировано от общего объема в %: 100
Результаты сканирования: no warnings, no errors
Подробнее смотри скриншот результатов проверки Victoria 4.47

--------- ADUReaport.txt ---------
Time Generated: Thursday December 08, 2016 12:07:50PM

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Physical Drive Status

SCSI Bus 0 (0x00)
SCSIID 5 (0x05)
Block Size 512 Bytes Per Block (0x0200)
Total Blocks 146.8 GB (0x11175330)
Reserved Blocks 0x00000440
Drive Model COMPAQ BF1468A4CC
Drive Serial Number 3KN28RD000009709PX47
Drive Firmware Revision HPB5
SCSI Inquiry Bits 0x3e
Compaq Drive Stamped Stamped For Monitoring (0x01)
Last Failure Reason No Failure (0x00)
Device Flags 0xcd
Position Device Flag Status
-------- ----------------------------- -------------
0 Drive Present And Operational Informational
2 Wide SCSI Transfers Enabled Informational
3 Synchronous Transfers Enabled Informational
6 Ultra SCSI Transfers Enabled Informational
7 Ultra2 SCSI Transfers Enabled Informational

More Device Flags 0x25
Position Device Flag Status
-------- ------------------------------------- -------------
0 SMART Predictive Failure Supported Informational
2 SMART Predictive Failure Is Enabled Informational
4 Device Attached To Internal Connector Informational
5 Configured Data Drive Informational

SCSI Lun 0x00
Yet More Device Flags 0x9d
Position Device Flag Status
-------- --------------------------------------- -------------
0 DT Clocking Mode Informational
2 DT And ST Clocking Supported Informational
3 U320 Transfers Enabled Informational
4 Supports Packetized SCSI Informational
7 Drive Write Cache Setting Is Changeable Informational

Even More Device Flags 0x05
Position Device Flag Status
-------- ------------------------- -------------
0 QAS Is Supported Informational
2 SCSI Arbitration Fairness Informational

Spi Speed Rules 0xf8b70800
Physical Port J1
Physical Box 0 (0x00)
Physical Bay 5 (0x05)
RPM 15000 RPM (0x00003aa7)
Device Type Parallel (0x00)
SATA Version 0x00
Big Total Block Count 0x0000000000000000
RIS Starting LBA 0x0000000000000000
RIS Size 0 MB (0x00000000)
WWID All Zeroes (20 x [0x00])
Controller PHY Map All Zeroes (32 x [0x00])
PHY Count 0 (0x0000)
PHY Connected Device Type All Zeroes (256 x [0x00])
PHY To Drive Bay Number All Zeroes (256 x [0x00])
PHY To Attached Device Index All Zeroes (256 x [0x0000])
Box Index 0 (0x00)
MSA Support 0x00
Extra Device Flags 0x0000
Negotiated Link Rate All Zeroes (256 x [0x00])
Phy To Phy Map All Zeroes (256 x [0x00])
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Multi LUN Device LUN Count 0x00
Minimum Good Firmware Revision empty
Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00])
Current Temperature 0x00
Temperature Threshold 0x00
Maximum Temperature 0x00
Logical Blocks Per Physical Block 0x00
Current Q Depth Limit 0x0000
Switch Name All Zeroes (10 x [0x00])
Switch Port 0x0000
Alternate Paths Switch Name All Zeroes (40 x [0x00])
Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Power On Hours 0x0000
Percent Endurance Used 0x0000
Drive Authentication 0x00
Smart Carrier Authentication 0x00
Smart Carrier Application Version 0x00
Smart Carrier Bootloader Version 0x00

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Factory)

Serial Number 3KN28RD000009709PX47
Firmware Revision HPB5
Product Revision COMPAQ BF1468A4CC
Reference Time 0x0033eedf
Sectors Read 0x00000039d9994309
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x000000000000000a
Sectors Written 0x000000115eaf752d
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Reset)

Serial Number 3KN28RD000009709PX47
Firmware Revision HPB5
Product Revision COMPAQ BF1468A4CC
Reference Time 0x0000005c
Sectors Read 0x0000000012028032
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x00000000000001fc
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0x0099
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Violations

Threshold Violation Flags All Zeroes (256 x [0x00])
Offset To Extended Threshold Violation Flags 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
Total Structure Length 0 (0x00000000)
Fixed Structure Length 0 (0x00000000)

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Parameter Control

Serial Number 0x8054
Firmware Revision 0x8248
Product Revision 0x8268
Reference Time 0x8184
Sectors Read 0x8108
Read Errors Hard 0x8184
Read Errors Retry Recovered 0x8184
Read Errors ECC Corrected 0x8188
Sectors Written 0x8108
Write Errors Hard 0x8184
Write Errors Retry Recovered 0x8184
Seek Count 33032 (0x8108)
Seek Errors 0x8188
Spin Cycles 0x8184
Spin Up Time 0x8a82
Performance Test 1 0x0a82
Performance Test 2 0x8a82
Performance Test 3 0x8a82
Performance Test 4 0x8a82
Reallocation Sects 0x0a04
Reallocated Sects 0x8d84
DRQ Timeouts 0x0982
Other Timeouts 0x0182
Drive Rebuild Count 386 (0x0182)
Spin Retries 2434 (0x0982)
Recovers Failed Read 0x8182
Recovers Failed Write 0x0182
Format Errors 0x0182
Self Test Failures 0x0982
Not Ready Failures 0x0184
Remap Abort Failures 0x0984
IRQ Deglitch Count 0x0984
Bus Faults 33156 (0x8184)
Hot Plug Count 0x0184
Track Rewrite Errors 0x0982
Write Errors After Remap 0x0982
Background Firmware Revision 0x0a48
Media Failures 0x0182
Hardware Errors 0x0182
Aborted Command Failures 0x0182
Spin Up Failures 0x0182
Bad Target Count 386 (0x0182)
Predictive Failure Errors 0x2184

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Parallel Scsi Physical Drive Error Log

Entry Size 20 (0x14)
Entry Count 20 (0x0014)
Next Entry Offset 0x0b
Errors Logged 11 (0x0000000b)
Physical Drive Error Log Entries Error Type SCSI Operation Code SCSI Status CAM Status Sense Key ASC ASCQ Block Valid Block Reference Time Additional Information
---------- ------------------- ----------- ---------- --------- ---- ---- ----------- ---------- -------------- ----------------------
0x02 0x28 0x00 0x0e 0x00 0x00 0x00 0x00 0x01b96bc0 0x0007a984 0x0000
0x01 0x28 0x02 0x04 0x01 0x18 0x02 0x01 0x05296fc3 0x00155912 0x0000
0x01 0x28 0x02 0x04 0x01 0x18 0x02 0x01 0x0574aa24 0x0027e30b 0x0000
0x01 0x28 0x02 0x04 0x01 0x18 0x02 0x01 0x0574aa20 0x00291c26 0x0000
0x01 0x28 0x02 0x04 0x01 0x18 0x02 0x01 0x05058c3c 0x0029b2c8 0x0000
0x01 0x28 0x02 0x04 0x01 0x18 0x02 0x01 0x05058c42 0x0029b2c8 0x0000
0x01 0x28 0x02 0x04 0x01 0x18 0x02 0x01 0x0574aa27 0x0029c544 0x0000
0x01 0x28 0x02 0x04 0x01 0x18 0x07 0x01 0x05058c28 0x0029c992 0x0000
0x01 0x28 0x02 0x04 0x01 0x18 0x02 0x01 0x0574b3b3 0x002a4a5c 0x0000
0x01 0x28 0x02 0x04 0x01 0x18 0x02 0x01 0x0528e732 0x002b01d0 0x0000
0x01 0x28 0x02 0x04 0x01 0x18 0x02 0x01 0x0574b3b0 0x002cf5c5 0x0000

Reference Time 0x0033eedf

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Mode Sense 10

Header 0x00 0xd6 0x00 0x10 0x00 0x00 0x00 0x08 0x00 0x00 0x00 0x00 0x00 0x00 0x02 0x00
Mode Page Page Number Page Data
----------- -----------------------------------------------------------------------------------------------------------------------
0x00 0x80 0x06 0x00 0x00 0x0f 0x00 0x00 0x00
0x01 0x81 0x0a 0xe4 0x0b 0xff 0x00 0x00 0x00 0x05 0x00 0xff 0xff
0x02 0x82 0x0e 0x80 0x80 0x00 0x0a 0x00 0x00 0x00 0x00 0x00 0x00 0x10 0x00 0x00 0x00
0x03 0x83 0x16 0x56 0x20 0x00 0x00 0x00 0x30 0x00 0x00 0x02 0xc2 0x02 0x00 0x00 0x01 0x00 0xdc 0x00 0xaa 0x40 0x00 0x00 0x00
0x04 0x84 0x16 0x00 0xc6 0x88 0x08 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x3a 0xa7 0x00 0x00
0x07 0x87 0x0a 0x04 0x0b 0xff 0x00 0x00 0x00 0x00 0x00 0xff 0xff
0x08 0x88 0x12 0x10 0x00 0xff 0xff 0x00 0x00 0xff 0xff 0xff 0xff 0x00 0x20 0x00 0x00 0x00 0x00 0x00 0x00
0x09 0x89 0x0e 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x04 0x00
0x0a 0x8a 0x0a 0x00 0x10 0x00 0x00 0x00 0x00 0x00 0x00 0x08 0x36
0x0c 0x8c 0x16 0x80 0x00 0x00 0x0f 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0xc6 0x87 0x07 0x00 0x00 0x00 0x00 0x00 0x00 0x10 0x08
0x19 0x19 0x06 0x01 0x00 0xff 0xff 0x00 0x00
0x1a 0x9a 0x0a 0x00 0x00 0xff 0xff 0xff 0xff 0xff 0xff 0xff 0xff
0x1c 0x9c 0x0a 0x11 0x04 0x00 0x00 0x0b 0xb8 0x00 0x00 0x00 0x02


Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : VPD Page 80 - Serial Number

Product Serial Number 3KN28RD000009709PX47

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : VPD Page 83 - Array Information

Array Code Set Identifier Type Association Identifier Length Identifier
-------- --------------- ----------- ----------------- ---------------------------------------------------------------------------------------------------------------------------------------------------------------
0x02 0x01 0x00 0x20 0x53 0x45 0x41 0x47 0x41 0x54 0x45 0x20 0x53 0x54 0x33 0x31 0x34 0x36 0x38 0x35 0x34 0x4c 0x43 0x20 0x20 0x20 0x20 0x20 0x33 0x4b 0x4e 0x32 0x38 0x52 0x44 0x30
0x01 0x03 0x00 0x08 0x50 0x01 0x86 0x20 0x00 0x87 0xa4 0x90


Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Sense Bus Parameters

Peripheral Type 0x03
RMB 0x00
Versions 0x02
Misc 0x02
Additional Length 0x23
Support Bits 0x00
Vendor ID COMPAQ
Product ID PROLIANT 6L2I
Product Revision 0.10
Inquiry Valid 0x01
Installed Drive Map 0x00000180
Hot Plug Count All Zeroes (32 x [0x0000])
Physical Box 0 (0x00)
Alarm Status 0x00
Temp Status 0x00
Valid Alarm Bits 0x00
Alarm Count 0 (0x0000)
Specific Alarm Counts All Zeroes (8 x [0x0000])
Connection Flags 0x010a
Position Connection Flag Status
-------- -------------------------- -------------
1 Internal Connector Is Used Informational
3 Proliant Storage Detected Informational

SCSI Device Revision 0x01
Fan Status 0x00
More Inquiry Data 0x03 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
SCSI Device Type 0x00460e11
Bus Map 0x00003f80
Interrupt Count 0 (0x00000000)
Ultra Bus Faults 0x00000000
SCSI Initiator ID 7 (0x07)
SCSI Target ID 7 (0x07)
Physical Port J2
Big Installed Drive Map 0x00 0x00 0x03 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Big Bus Map 0x00 0x00 0xff 0xff 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Big Box Map 0x00 0x00 0x3f 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Installed Box Map 0x01
More Connection Flags 0x01
Position Connection Flag Status
-------- ------------------- -------------
0 Running In Lvd Mode Informational
2 Using Id Numbering Informational

Bay Count 0 (0x00)
Expander Count 0 (0x00)
Chassis Serial Number empty
Fast Bus Faults 0x00000000
Ultra 2 Bus Faults 0x00000000
Ultra 3 Bus Faults 0x00000000
Ultra 320 Bus Faults 0x00000002
SEP Count 0 (0x00)
SEP Device Types All Zeroes (16 x [0x00])
SEP Device Numbers All Zeroes (16 x [0x0000])
Expander Device Numbers All Zeroes (16 x [0x0000])
Offset To Extended Installed Drive Map 0 (0x0000)
Offset To Extended Bus Map 0 (0x0000)
Offset To Extended Box Map 0 (0x0000)
Total Structure Length 0 (0x00000000)
Offset To Element Type Modules 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
IO Module Present Map 0x00
Active IO Module Number 0x00
IO Module Failure Map 0x00
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Zoned In Enclosure Bay Map All Zeroes (32 x [0x00])
Position Zoned In Enclosure Bay Status
-------- ---------------------- -------------
0 False Informational
1 False Informational
2 False Informational
3 False Informational
4 False Informational
5 False Informational
6 False Informational
7 False Informational
8 False Informational
9 False Informational
10 False Informational
11 False Informational
12 False Informational
13 False Informational
14 False Informational
15 False Informational
16 False Informational
17 False Informational
18 False Informational
19 False Informational
20 False Informational
21 False Informational
22 False Informational
23 False Informational
24 False Informational
25 False Informational
26 False Informational
27 False Informational
28 False Informational
29 False Informational
30 False Informational
31 False Informational
32 False Informational
33 False Informational
34 False Informational
35 False Informational
36 False Informational
37 False Informational
38 False Informational
39 False Informational
40 False Informational
41 False Informational
42 False Informational
43 False Informational
44 False Informational
45 False Informational
46 False Informational
47 False Informational
48 False Informational
49 False Informational
50 False Informational
51 False Informational
52 False Informational
53 False Informational
54 False Informational
55 False Informational
56 False Informational
57 False Informational
58 False Informational
59 False Informational
60 False Informational
61 False Informational
62 False Informational
63 False Informational
64 False Informational
65 False Informational
66 False Informational
67 False Informational
68 False Informational
69 False Informational
70 False Informational
71 False Informational
72 False Informational
73 False Informational
74 False Informational
75 False Informational
76 False Informational
77 False Informational
78 False Informational
79 False Informational
80 False Informational
81 False Informational
82 False Informational
83 False Informational
84 False Informational
85 False Informational
86 False Informational
87 False Informational
88 False Informational
89 False Informational
90 False Informational
91 False Informational
92 False Informational
93 False Informational
94 False Informational
95 False Informational
96 False Informational
97 False Informational
98 False Informational
99 False Informational
100 False Informational
101 False Informational
102 False Informational
103 False Informational
104 False Informational
105 False Informational
106 False Informational
107 False Informational
108 False Informational
109 False Informational
110 False Informational
111 False Informational
112 False Informational
113 False Informational
114 False Informational
115 False Informational
116 False Informational
117 False Informational
118 False Informational
119 False Informational
120 False Informational
121 False Informational
122 False Informational
123 False Informational
124 False Informational
125 False Informational
126 False Informational
127 False Informational

Fixed Structure Length 0 (0x00000000)
Big Hot Plug Count All Zeroes (256 x [0x0000])

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Sense Bus Parameters

Peripheral Type 0x03
RMB 0x00
Versions 0x02
Misc 0x02
Additional Length 0x23
Support Bits 0x00
Vendor ID COMPAQ
Product ID PROLIANT 6L2I
Product Revision 0.10
Inquiry Valid 0x01
Installed Drive Map 0x00000180
Hot Plug Count All Zeroes (32 x [0x0000])
Physical Box 0 (0x00)
Alarm Status 0x00
Temp Status 0x00
Valid Alarm Bits 0x00
Alarm Count 0 (0x0000)
Specific Alarm Counts All Zeroes (8 x [0x0000])
Connection Flags 0x010a
Position Connection Flag Status
-------- -------------------------- -------------
1 Internal Connector Is Used Informational
3 Proliant Storage Detected Informational

SCSI Device Revision 0x01
Fan Status 0x00
More Inquiry Data 0x03 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
SCSI Device Type 0x00460e11
Bus Map 0x00003f80
Interrupt Count 0 (0x00000000)
Ultra Bus Faults 0x00000000
SCSI Initiator ID 7 (0x07)
SCSI Target ID 7 (0x07)
Physical Port J2
Big Installed Drive Map 0x00 0x00 0x03 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Big Bus Map 0x00 0x00 0xff 0xff 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Big Box Map 0x00 0x00 0x3f 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Installed Box Map 0x01
More Connection Flags 0x01
Position Connection Flag Status
-------- ------------------- -------------
0 Running In Lvd Mode Informational
2 Using Id Numbering Informational

Bay Count 0 (0x00)
Expander Count 0 (0x00)
Chassis Serial Number empty
Fast Bus Faults 0x00000000
Ultra 2 Bus Faults 0x00000000
Ultra 3 Bus Faults 0x00000000
Ultra 320 Bus Faults 0x00000002
SEP Count 0 (0x00)
SEP Device Types All Zeroes (16 x [0x00])
SEP Device Numbers All Zeroes (16 x [0x0000])
Expander Device Numbers All Zeroes (16 x [0x0000])
Offset To Extended Installed Drive Map 0 (0x0000)
Offset To Extended Bus Map 0 (0x0000)
Offset To Extended Box Map 0 (0x0000)
Total Structure Length 0 (0x00000000)
Offset To Element Type Modules 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
IO Module Present Map 0x00
Active IO Module Number 0x00
IO Module Failure Map 0x00
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Zoned In Enclosure Bay Map All Zeroes (32 x [0x00])
Position Zoned In Enclosure Bay Status
-------- ---------------------- -------------
0 False Informational
1 False Informational
2 False Informational
3 False Informational
4 False Informational
5 False Informational
6 False Informational
7 False Informational
8 False Informational
9 False Informational
10 False Informational
11 False Informational
12 False Informational
13 False Informational
14 False Informational
15 False Informational
16 False Informational
17 False Informational
18 False Informational
19 False Informational
20 False Informational
21 False Informational
22 False Informational
23 False Informational
24 False Informational
25 False Informational
26 False Informational
27 False Informational
28 False Informational
29 False Informational
30 False Informational
31 False Informational
32 False Informational
33 False Informational
34 False Informational
35 False Informational
36 False Informational
37 False Informational
38 False Informational
39 False Informational
40 False Informational
41 False Informational
42 False Informational
43 False Informational
44 False Informational
45 False Informational
46 False Informational
47 False Informational
48 False Informational
49 False Informational
50 False Informational
51 False Informational
52 False Informational
53 False Informational
54 False Informational
55 False Informational
56 False Informational
57 False Informational
58 False Informational
59 False Informational
60 False Informational
61 False Informational
62 False Informational
63 False Informational
64 False Informational
65 False Informational
66 False Informational
67 False Informational
68 False Informational
69 False Informational
70 False Informational
71 False Informational
72 False Informational
73 False Informational
74 False Informational
75 False Informational
76 False Informational
77 False Informational
78 False Informational
79 False Informational
80 False Informational
81 False Informational
82 False Informational
83 False Informational
84 False Informational
85 False Informational
86 False Informational
87 False Informational
88 False Informational
89 False Informational
90 False Informational
91 False Informational
92 False Informational
93 False Informational
94 False Informational
95 False Informational
96 False Informational
97 False Informational
98 False Informational
99 False Informational
100 False Informational
101 False Informational
102 False Informational
103 False Informational
104 False Informational
105 False Informational
106 False Informational
107 False Informational
108 False Informational
109 False Informational
110 False Informational
111 False Informational
112 False Informational
113 False Informational
114 False Informational
115 False Informational
116 False Informational
117 False Informational
118 False Informational
119 False Informational
120 False Informational
121 False Informational
122 False Informational
123 False Informational
124 False Informational
125 False Informational
126 False Informational
127 False Informational

Fixed Structure Length 0 (0x00000000)
Big Hot Plug Count All Zeroes (256 x [0x0000])

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (72.8 GB Parallel SCSI) 2:0 : Physical Drive Status

SCSI Bus 1 (0x01)
SCSIID 0 (0x00)
Block Size 512 Bytes Per Block (0x0200)
Total Blocks 72.8 GB (0x087aa6c0)
Reserved Blocks 0x00000440
Drive Model COMPAQ BD0728A4C4
Drive Serial Number 3KT4K52P00007643LVT8
Drive Firmware Revision HPB4
SCSI Inquiry Bits 0x3e
Compaq Drive Stamped Stamped For Monitoring (0x01)
Last Failure Reason No Failure (0x00)
Device Flags 0xcd
Position Device Flag Status
-------- ----------------------------- -------------
0 Drive Present And Operational Informational
2 Wide SCSI Transfers Enabled Informational
3 Synchronous Transfers Enabled Informational
6 Ultra SCSI Transfers Enabled Informational
7 Ultra2 SCSI Transfers Enabled Informational

More Device Flags 0x25
Position Device Flag Status
-------- ------------------------------------- -------------
0 SMART Predictive Failure Supported Informational
2 SMART Predictive Failure Is Enabled Informational
4 Device Attached To Internal Connector Informational
5 Configured Data Drive Informational

SCSI Lun 0x00
Yet More Device Flags 0x9d
Position Device Flag Status
-------- --------------------------------------- -------------
0 DT Clocking Mode Informational
2 DT And ST Clocking Supported Informational
3 U320 Transfers Enabled Informational
4 Supports Packetized SCSI Informational
7 Drive Write Cache Setting Is Changeable Informational

Even More Device Flags 0x07
Position Device Flag Status
-------- ------------------------- -------------
0 QAS Is Supported Informational
1 QAS Is Enabled Informational
2 SCSI Arbitration Fairness Informational

Spi Speed Rules 0xf8b70800
Physical Port J2
Physical Box 0 (0x00)
Physical Bay 0 (0x00)
RPM 10000 RPM (0x00002731)
Device Type Parallel (0x00)
SATA Version 0x00
Big Total Block Count 0x0000000000000000
RIS Starting LBA 0x0000000000000000
RIS Size 0 MB (0x00000000)
WWID All Zeroes (20 x [0x00])
Controller PHY Map All Zeroes (32 x [0x00])
PHY Count 0 (0x0000)
PHY Connected Device Type All Zeroes (256 x [0x00])
PHY To Drive Bay Number All Zeroes (256 x [0x00])
PHY To Attached Device Index All Zeroes (256 x [0x0000])
Box Index 0 (0x00)
MSA Support 0x00
Extra Device Flags 0x0000
Negotiated Link Rate All Zeroes (256 x [0x00])
Phy To Phy Map All Zeroes (256 x [0x00])
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Multi LUN Device LUN Count 0x00
Minimum Good Firmware Revision empty
Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00])
Current Temperature 0x00
Temperature Threshold 0x00
Maximum Temperature 0x00
Logical Blocks Per Physical Block 0x00
Current Q Depth Limit 0x0000
Switch Name All Zeroes (10 x [0x00])
Switch Port 0x0000
Alternate Paths Switch Name All Zeroes (40 x [0x00])
Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Power On Hours 0x0000
Percent Endurance Used 0x0000
Drive Authentication 0x00
Smart Carrier Authentication 0x00
Smart Carrier Application Version 0x00
Smart Carrier Bootloader Version 0x00

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (72.8 GB Parallel SCSI) 2:0 : Monitor and Performance Statistics (Since Factory)

Serial Number 3KT4K52P00007643LVT8
Firmware Revision HPB4
Product Revision COMPAQ BD0728A4C4
Reference Time 0x003b9558
Sectors Read 0x000000443cdd5f29
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x0000000bac7e6e5e
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000000
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (72.8 GB Parallel SCSI) 2:0 : Monitor and Performance Statistics (Since Reset)

Serial Number 3KT4K52P00007643LVT8
Firmware Revision HPB4
Product Revision COMPAQ BD0728A4C4
Reference Time 0x0000006c
Sectors Read 0x00000000000eabb1
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x000000000001a3b7
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs

800 ₽
800 ₽
BF1468A4CC, no warnings, no errors

Комплектация:
HDD HP BF1468A4B3
Салазки HP Spare 404712-001

Тест поверхности:
Сектор начала тестирования: 0
Сектор конца тестирования: 286 734 239
Протестировано от общего объема в %: 100
Результаты сканирования: no warnings, no errors
Подробнее смотри скриншот результатов проверки Victoria 4.47

--------- ADUReaport.txt ---------
Time Generated: Thursday December 08, 2016 3:24:09PM

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Physical Drive Status

SCSI Bus 0 (0x00)
SCSIID 5 (0x05)
Block Size 512 Bytes Per Block (0x0200)
Total Blocks 146.8 GB (0x11175330)
Reserved Blocks 0x00000440
Drive Model COMPAQ BF1468A4B3
Drive Serial Number JAXMJ05K
Drive Firmware Revision HPB5
SCSI Inquiry Bits 0x3a
Compaq Drive Stamped Stamped For Monitoring (0x01)
Last Failure Reason Hot Removed (0x14)
Device Flags 0xcd
Position Device Flag Status
-------- ----------------------------- -------------
0 Drive Present And Operational Informational
2 Wide SCSI Transfers Enabled Informational
3 Synchronous Transfers Enabled Informational
6 Ultra SCSI Transfers Enabled Informational
7 Ultra2 SCSI Transfers Enabled Informational

More Device Flags 0x25
Position Device Flag Status
-------- ------------------------------------- -------------
0 SMART Predictive Failure Supported Informational
2 SMART Predictive Failure Is Enabled Informational
4 Device Attached To Internal Connector Informational
5 Configured Data Drive Informational

SCSI Lun 0x00
Yet More Device Flags 0x9d
Position Device Flag Status
-------- --------------------------------------- -------------
0 DT Clocking Mode Informational
2 DT And ST Clocking Supported Informational
3 U320 Transfers Enabled Informational
4 Supports Packetized SCSI Informational
7 Drive Write Cache Setting Is Changeable Informational

Even More Device Flags 0x05
Position Device Flag Status
-------- ------------------------- -------------
0 QAS Is Supported Informational
2 SCSI Arbitration Fairness Informational

Spi Speed Rules 0xf8b70800
Physical Port J1
Physical Box 0 (0x00)
Physical Bay 5 (0x05)
RPM 15000 RPM (0x00003a98)
Device Type Parallel (0x00)
SATA Version 0x00
Big Total Block Count 0x0000000000000000
RIS Starting LBA 0x0000000000000000
RIS Size 0 MB (0x00000000)
WWID All Zeroes (20 x [0x00])
Controller PHY Map All Zeroes (32 x [0x00])
PHY Count 0 (0x0000)
PHY Connected Device Type All Zeroes (256 x [0x00])
PHY To Drive Bay Number All Zeroes (256 x [0x00])
PHY To Attached Device Index All Zeroes (256 x [0x0000])
Box Index 0 (0x00)
MSA Support 0x00
Extra Device Flags 0x0000
Negotiated Link Rate All Zeroes (256 x [0x00])
Phy To Phy Map All Zeroes (256 x [0x00])
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Multi LUN Device LUN Count 0x00
Minimum Good Firmware Revision empty
Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00])
Current Temperature 0x00
Temperature Threshold 0x00
Maximum Temperature 0x00
Logical Blocks Per Physical Block 0x00
Current Q Depth Limit 0x0000
Switch Name All Zeroes (10 x [0x00])
Switch Port 0x0000
Alternate Paths Switch Name All Zeroes (40 x [0x00])
Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Power On Hours 0x0000
Percent Endurance Used 0x0000
Drive Authentication 0x00
Smart Carrier Authentication 0x00
Smart Carrier Application Version 0x00
Smart Carrier Bootloader Version 0x00

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Factory)

Serial Number JAXMJ05K
Firmware Revision HPB5
Product Revision COMPAQ BF1468A4B3
Reference Time 0x002c4592
Sectors Read 0x00000033cb9e7b4e
Read Errors Hard 0x000016cd
Read Errors Retry Recovered 0x000000b9
Read Errors ECC Corrected 0x000000000000004d
Sectors Written 0x0000000f02d28a63
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000002
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x003c
Drive Rebuild Count 1 (0x0001)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Reset)

Serial Number JAXMJ05K
Firmware Revision HPB5
Product Revision COMPAQ BF1468A4B3
Reference Time 0x00000094
Sectors Read 0x0000000011173a89
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x0000000000000219
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0x00a3
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Violations

Threshold Violation Flags All Zeroes (256 x [0x00])
Offset To Extended Threshold Violation Flags 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
Total Structure Length 0 (0x00000000)
Fixed Structure Length 0 (0x00000000)

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Parameter Control

Serial Number 0x8054
Firmware Revision 0x8248
Product Revision 0x8268
Reference Time 0x8184
Sectors Read 0x8108
Read Errors Hard 0x8184
Read Errors Retry Recovered 0x8184
Read Errors ECC Corrected 0x8188
Sectors Written 0x8108
Write Errors Hard 0x8184
Write Errors Retry Recovered 0x8184
Seek Count 33032 (0x8108)
Seek Errors 0x8188
Spin Cycles 0x8184
Spin Up Time 0x8a82
Performance Test 1 0x0a82
Performance Test 2 0x8a82
Performance Test 3 0x8a82
Performance Test 4 0x8a82
Reallocation Sects 0x0a04
Reallocated Sects 0x8d84
DRQ Timeouts 0x0982
Other Timeouts 0x0182
Drive Rebuild Count 386 (0x0182)
Spin Retries 2434 (0x0982)
Recovers Failed Read 0x8182
Recovers Failed Write 0x0182
Format Errors 0x0182
Self Test Failures 0x0982
Not Ready Failures 0x0184
Remap Abort Failures 0x0984
IRQ Deglitch Count 0x0984
Bus Faults 33156 (0x8184)
Hot Plug Count 0x0184
Track Rewrite Errors 0x0982
Write Errors After Remap 0x0982
Background Firmware Revision 0x0a48
Media Failures 0x0182
Hardware Errors 0x0182
Aborted Command Failures 0x0182
Spin Up Failures 0x0182
Bad Target Count 386 (0x0182)
Predictive Failure Errors 0x2184

800 ₽
800 ₽
BF1468A4B3, no warnings, no errors

Комплектация:
HDD HP BF1468A4CC
Салазки HP Spare 404712-001

Тест поверхности:
Сектор начала тестирования: 0
Сектор конца тестирования: 286 734 239
Протестировано от общего объема в %: 100
Результаты сканирования: no warnings, no errors
Подробнее смотри скриншот результатов проверки Victoria 4.47

--------- ADUReaport.txt ---------
Time Generated: Thursday December 08, 2016 3:24:09PM

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Physical Drive Status

SCSI Bus 0 (0x00)
SCSIID 3 (0x03)
Block Size 512 Bytes Per Block (0x0200)
Total Blocks 146.8 GB (0x11175330)
Reserved Blocks 0x00000440
Drive Model COMPAQ BF1468A4CC
Drive Serial Number 3KN2APLX00009708BSQP
Drive Firmware Revision HPB5
SCSI Inquiry Bits 0x3e
Compaq Drive Stamped Stamped For Monitoring (0x01)
Last Failure Reason Hot Removed (0x14)
Device Flags 0xcd
Position Device Flag Status
-------- ----------------------------- -------------
0 Drive Present And Operational Informational
2 Wide SCSI Transfers Enabled Informational
3 Synchronous Transfers Enabled Informational
6 Ultra SCSI Transfers Enabled Informational
7 Ultra2 SCSI Transfers Enabled Informational

More Device Flags 0x25
Position Device Flag Status
-------- ------------------------------------- -------------
0 SMART Predictive Failure Supported Informational
2 SMART Predictive Failure Is Enabled Informational
4 Device Attached To Internal Connector Informational
5 Configured Data Drive Informational

SCSI Lun 0x00
Yet More Device Flags 0x9d
Position Device Flag Status
-------- --------------------------------------- -------------
0 DT Clocking Mode Informational
2 DT And ST Clocking Supported Informational
3 U320 Transfers Enabled Informational
4 Supports Packetized SCSI Informational
7 Drive Write Cache Setting Is Changeable Informational

Even More Device Flags 0x05
Position Device Flag Status
-------- ------------------------- -------------
0 QAS Is Supported Informational
2 SCSI Arbitration Fairness Informational

Spi Speed Rules 0xf8b70800
Physical Port J1
Physical Box 0 (0x00)
Physical Bay 3 (0x03)
RPM 15000 RPM (0x00003aa7)
Device Type Parallel (0x00)
SATA Version 0x00
Big Total Block Count 0x0000000000000000
RIS Starting LBA 0x0000000000000000
RIS Size 0 MB (0x00000000)
WWID All Zeroes (20 x [0x00])
Controller PHY Map All Zeroes (32 x [0x00])
PHY Count 0 (0x0000)
PHY Connected Device Type All Zeroes (256 x [0x00])
PHY To Drive Bay Number All Zeroes (256 x [0x00])
PHY To Attached Device Index All Zeroes (256 x [0x0000])
Box Index 0 (0x00)
MSA Support 0x00
Extra Device Flags 0x0000
Negotiated Link Rate All Zeroes (256 x [0x00])
Phy To Phy Map All Zeroes (256 x [0x00])
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Multi LUN Device LUN Count 0x00
Minimum Good Firmware Revision empty
Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00])
Current Temperature 0x00
Temperature Threshold 0x00
Maximum Temperature 0x00
Logical Blocks Per Physical Block 0x00
Current Q Depth Limit 0x0000
Switch Name All Zeroes (10 x [0x00])
Switch Port 0x0000
Alternate Paths Switch Name All Zeroes (40 x [0x00])
Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Power On Hours 0x0000
Percent Endurance Used 0x0000
Drive Authentication 0x00
Smart Carrier Authentication 0x00
Smart Carrier Application Version 0x00
Smart Carrier Bootloader Version 0x00

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Factory)

Serial Number 3KN2APLX00009708BSQP
Firmware Revision HPB5
Product Revision COMPAQ BF1468A4CC
Reference Time 0x0033ef17
Sectors Read 0x00000038cf82416f
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x000000115cb129c3
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Reset)

Serial Number 3KN2APLX00009708BSQP
Firmware Revision HPB5
Product Revision COMPAQ BF1468A4CC
Reference Time 0x00000094
Sectors Read 0x00000000111738bd
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x0000000000000634
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0x0088
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Violations

Threshold Violation Flags All Zeroes (256 x [0x00])
Offset To Extended Threshold Violation Flags 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
Total Structure Length 0 (0x00000000)
Fixed Structure Length 0 (0x00000000)

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Parameter Control

Serial Number 0x8054
Firmware Revision 0x8248
Product Revision 0x8268
Reference Time 0x8184
Sectors Read 0x8108
Read Errors Hard 0x8184
Read Errors Retry Recovered 0x8184
Read Errors ECC Corrected 0x8188
Sectors Written 0x8108
Write Errors Hard 0x8184
Write Errors Retry Recovered 0x8184
Seek Count 33032 (0x8108)
Seek Errors 0x8188
Spin Cycles 0x8184
Spin Up Time 0x8a82
Performance Test 1 0x0a82
Performance Test 2 0x8a82
Performance Test 3 0x8a82
Performance Test 4 0x8a82
Reallocation Sects 0x0a04
Reallocated Sects 0x8d84
DRQ Timeouts 0x0982
Other Timeouts 0x0182
Drive Rebuild Count 386 (0x0182)
Spin Retries 2434 (0x0982)
Recovers Failed Read 0x8182
Recovers Failed Write 0x0182
Format Errors 0x0182
Self Test Failures 0x0982
Not Ready Failures 0x0184
Remap Abort Failures 0x0984
IRQ Deglitch Count 0x0984
Bus Faults 33156 (0x8184)
Hot Plug Count 0x0184
Track Rewrite Errors 0x0982
Write Errors After Remap 0x0982
Background Firmware Revision 0x0a48
Media Failures 0x0182
Hardware Errors 0x0182
Aborted Command Failures 0x0182
Spin Up Failures 0x0182
Bad Target Count 386 (0x0182)
Predictive Failure Errors 0x2184

800 ₽
800 ₽
BF1468A4CC, no warnings, no errors

Комплектация:
HDD HP BF1468A4BB
Салазки HP Spare 404712-001

Тест поверхности:
Сектор начала тестирования: 0
Сектор конца тестирования: 286 734 239
Протестировано от общего объема в %: 100
Результаты сканирования: no warnings, no errors
Подробнее смотри скриншот результатов проверки Victoria 4.47

--------- ADUReaport.txt ---------
Time Generated: Thursday December 08, 2016 3:24:09PM


Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Physical Drive Status

SCSI Bus 0 (0x00)
SCSIID 2 (0x02)
Block Size 512 Bytes Per Block (0x0200)
Total Blocks 146.8 GB (0x11175330)
Reserved Blocks 0x00000440
Drive Model COMPAQ BF1468A4BB
Drive Serial Number K80923GK
Drive Firmware Revision HPB7
SCSI Inquiry Bits 0x3e
Compaq Drive Stamped Stamped For Monitoring (0x01)
Last Failure Reason Hot Removed (0x14)
Device Flags 0xcd
Position Device Flag Status
-------- ----------------------------- -------------
0 Drive Present And Operational Informational
2 Wide SCSI Transfers Enabled Informational
3 Synchronous Transfers Enabled Informational
6 Ultra SCSI Transfers Enabled Informational
7 Ultra2 SCSI Transfers Enabled Informational

More Device Flags 0x25
Position Device Flag Status
-------- ------------------------------------- -------------
0 SMART Predictive Failure Supported Informational
2 SMART Predictive Failure Is Enabled Informational
4 Device Attached To Internal Connector Informational
5 Configured Data Drive Informational

SCSI Lun 0x00
Yet More Device Flags 0x9d
Position Device Flag Status
-------- --------------------------------------- -------------
0 DT Clocking Mode Informational
2 DT And ST Clocking Supported Informational
3 U320 Transfers Enabled Informational
4 Supports Packetized SCSI Informational
7 Drive Write Cache Setting Is Changeable Informational

Even More Device Flags 0x05
Position Device Flag Status
-------- ------------------------- -------------
0 QAS Is Supported Informational
2 SCSI Arbitration Fairness Informational

Spi Speed Rules 0xf8b70800
Physical Port J1
Physical Box 0 (0x00)
Physical Bay 2 (0x02)
RPM 15000 RPM (0x00003aa8)
Device Type Parallel (0x00)
SATA Version 0x00
Big Total Block Count 0x0000000000000000
RIS Starting LBA 0x0000000000000000
RIS Size 0 MB (0x00000000)
WWID All Zeroes (20 x [0x00])
Controller PHY Map All Zeroes (32 x [0x00])
PHY Count 0 (0x0000)
PHY Connected Device Type All Zeroes (256 x [0x00])
PHY To Drive Bay Number All Zeroes (256 x [0x00])
PHY To Attached Device Index All Zeroes (256 x [0x0000])
Box Index 0 (0x00)
MSA Support 0x00
Extra Device Flags 0x0000
Negotiated Link Rate All Zeroes (256 x [0x00])
Phy To Phy Map All Zeroes (256 x [0x00])
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Multi LUN Device LUN Count 0x00
Minimum Good Firmware Revision empty
Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00])
Current Temperature 0x00
Temperature Threshold 0x00
Maximum Temperature 0x00
Logical Blocks Per Physical Block 0x00
Current Q Depth Limit 0x0000
Switch Name All Zeroes (10 x [0x00])
Switch Port 0x0000
Alternate Paths Switch Name All Zeroes (40 x [0x00])
Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Power On Hours 0x0000
Percent Endurance Used 0x0000
Drive Authentication 0x00
Smart Carrier Authentication 0x00
Smart Carrier Application Version 0x00
Smart Carrier Bootloader Version 0x00

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Factory)

Serial Number K80923GK
Firmware Revision HPB7
Product Revision COMPAQ BF1468A4BB
Reference Time 0x003c7604
Sectors Read 0x0000005a4dfdf596
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x00000016160520f2
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Reset)

Serial Number K80923GK
Firmware Revision HPB7
Product Revision COMPAQ BF1468A4BB
Reference Time 0x00000094
Sectors Read 0x0000000011174024
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x00000000000007f5
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0x00c0
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Violations

Threshold Violation Flags All Zeroes (256 x [0x00])
Offset To Extended Threshold Violation Flags 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
Total Structure Length 0 (0x00000000)
Fixed Structure Length 0 (0x00000000)

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Parameter Control

Serial Number 0x8054
Firmware Revision 0x8248
Product Revision 0x8268
Reference Time 0x8184
Sectors Read 0x8108
Read Errors Hard 0x8184
Read Errors Retry Recovered 0x8184
Read Errors ECC Corrected 0x8188
Sectors Written 0x8108
Write Errors Hard 0x8184
Write Errors Retry Recovered 0x8184
Seek Count 33032 (0x8108)
Seek Errors 0x8188
Spin Cycles 0x8184
Spin Up Time 0x8a82
Performance Test 1 0x0a82
Performance Test 2 0x8a82
Performance Test 3 0x8a82
Performance Test 4 0x8a82
Reallocation Sects 0x0a04
Reallocated Sects 0x8d84
DRQ Timeouts 0x0982
Other Timeouts 0x0182
Drive Rebuild Count 386 (0x0182)
Spin Retries 2434 (0x0982)
Recovers Failed Read 0x8182
Recovers Failed Write 0x0182
Format Errors 0x0182
Self Test Failures 0x0982
Not Ready Failures 0x0184
Remap Abort Failures 0x0984
IRQ Deglitch Count 0x0984
Bus Faults 33156 (0x8184)
Hot Plug Count 0x0184
Track Rewrite Errors 0x0982
Write Errors After Remap 0x0982
Background Firmware Revision 0x0a48
Media Failures 0x0182
Hardware Errors 0x0182
Aborted Command Failures 0x0182
Spin Up Failures 0x0182
Bad Target Count 386 (0x0182)
Predictive Failure Errors 0x2184

800 ₽
800 ₽
BF1468A4BB, no warnings, no errors

Комплектация:
HDD HP BF1468A4CC, P/N: 360209-011
Салазки HP Spare 404712-001

Тест поверхности:
Сектор начала тестирования: 0
Сектор конца тестирования: 286 734 239
Протестировано от общего объема в %: 100
Результаты сканирования: no warnings, no errors
Подробнее смотри скриншот результатов проверки Victoria 4.47

--------- ADUReaport.txt ---------
Time Generated: Thursday December 08, 2016 6:44:20PM


Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Physical Drive Status

SCSI Bus 0 (0x00)
SCSIID 2 (0x02)
Block Size 512 Bytes Per Block (0x0200)
Total Blocks 146.8 GB (0x11175330)
Reserved Blocks 0x00000440
Drive Model COMPAQ BF1468A4CC
Drive Serial Number 3KN1M6NW00007644FH69
Drive Firmware Revision HPB5
SCSI Inquiry Bits 0x3e
Compaq Drive Stamped Stamped For Monitoring (0x01)
Last Failure Reason Hot Removed (0x14)
Device Flags 0xcd
Position Device Flag Status
-------- ----------------------------- -------------
0 Drive Present And Operational Informational
2 Wide SCSI Transfers Enabled Informational
3 Synchronous Transfers Enabled Informational
6 Ultra SCSI Transfers Enabled Informational
7 Ultra2 SCSI Transfers Enabled Informational

More Device Flags 0x25
Position Device Flag Status
-------- ------------------------------------- -------------
0 SMART Predictive Failure Supported Informational
2 SMART Predictive Failure Is Enabled Informational
4 Device Attached To Internal Connector Informational
5 Configured Data Drive Informational

SCSI Lun 0x00
Yet More Device Flags 0x95
Position Device Flag Status
-------- --------------------------------------- -------------
0 DT Clocking Mode Informational
2 DT And ST Clocking Supported Informational
4 Supports Packetized SCSI Informational
7 Drive Write Cache Setting Is Changeable Informational

Even More Device Flags 0x05
Position Device Flag Status
-------- ------------------------- -------------
0 QAS Is Supported Informational
2 SCSI Arbitration Fairness Informational

Spi Speed Rules 0xf8b70800
Physical Port J1
Physical Box 0 (0x00)
Physical Bay 2 (0x02)
RPM 15000 RPM (0x00003aa7)
Device Type Parallel (0x00)
SATA Version 0x00
Big Total Block Count 0x0000000000000000
RIS Starting LBA 0x0000000000000000
RIS Size 0 MB (0x00000000)
WWID All Zeroes (20 x [0x00])
Controller PHY Map All Zeroes (32 x [0x00])
PHY Count 0 (0x0000)
PHY Connected Device Type All Zeroes (256 x [0x00])
PHY To Drive Bay Number All Zeroes (256 x [0x00])
PHY To Attached Device Index All Zeroes (256 x [0x0000])
Box Index 0 (0x00)
MSA Support 0x00
Extra Device Flags 0x0000
Negotiated Link Rate All Zeroes (256 x [0x00])
Phy To Phy Map All Zeroes (256 x [0x00])
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Multi LUN Device LUN Count 0x00
Minimum Good Firmware Revision empty
Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00])
Current Temperature 0x00
Temperature Threshold 0x00
Maximum Temperature 0x00
Logical Blocks Per Physical Block 0x00
Current Q Depth Limit 0x0000
Switch Name All Zeroes (10 x [0x00])
Switch Port 0x0000
Alternate Paths Switch Name All Zeroes (40 x [0x00])
Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Power On Hours 0x0000
Percent Endurance Used 0x0000
Drive Authentication 0x00
Smart Carrier Authentication 0x00
Smart Carrier Application Version 0x00
Smart Carrier Bootloader Version 0x00

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Factory)

Serial Number 3KN1M6NW00007644FH69
Firmware Revision HPB5
Product Revision COMPAQ BF1468A4CC
Reference Time 0x003c7625
Sectors Read 0x00000059f8551f11
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x00000016122f339a
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Reset)

Serial Number 3KN1M6NW00007644FH69
Firmware Revision HPB5
Product Revision COMPAQ BF1468A4CC
Reference Time 0x000000ad
Sectors Read 0x0000000011173905
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x000000000000019c
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000000
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Violations

Threshold Violation Flags All Zeroes (256 x [0x00])
Offset To Extended Threshold Violation Flags 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
Total Structure Length 0 (0x00000000)
Fixed Structure Length 0 (0x00000000)

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Parameter Control

Serial Number 0x8054
Firmware Revision 0x8248
Product Revision 0x8268
Reference Time 0x8184
Sectors Read 0x8108
Read Errors Hard 0x8184
Read Errors Retry Recovered 0x8184
Read Errors ECC Corrected 0x8188
Sectors Written 0x8108
Write Errors Hard 0x8184
Write Errors Retry Recovered 0x8184
Seek Count 33032 (0x8108)
Seek Errors 0x8188
Spin Cycles 0x8184
Spin Up Time 0x8a82
Performance Test 1 0x0a82
Performance Test 2 0x8a82
Performance Test 3 0x8a82
Performance Test 4 0x8a82
Reallocation Sects 0x0a04
Reallocated Sects 0x8d84
DRQ Timeouts 0x0982
Other Timeouts 0x0182
Drive Rebuild Count 386 (0x0182)
Spin Retries 2434 (0x0982)
Recovers Failed Read 0x8182
Recovers Failed Write 0x0182
Format Errors 0x0182
Self Test Failures 0x0982
Not Ready Failures 0x0184
Remap Abort Failures 0x0984
IRQ Deglitch Count 0x0984
Bus Faults 33156 (0x8184)
Hot Plug Count 0x0184
Track Rewrite Errors 0x0982
Write Errors After Remap 0x0982
Background Firmware Revision 0x0a48
Media Failures 0x0182
Hardware Errors 0x0182
Aborted Command Failures 0x0182
Spin Up Failures 0x0182
Bad Target Count 386 (0x0182)
Predictive Failure Errors 0x2184

800 ₽
800 ₽
BF1468A4CC, no warnings, no errors

Комплектация:
HDD HP BF1468A4B3, P/N: 321499-006
Салазки HP Spare 404712-001

Тест поверхности:
Сектор начала тестирования: 0
Сектор конца тестирования: 286 734 239
Протестировано от общего объема в %: 100
Результаты сканирования: no warnings, no errors
Подробнее смотри скриншот результатов проверки Victoria 4.47

--------- ADUReaport.txt ---------
Time Generated: Thursday December 08, 2016 6:44:20PM

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Physical Drive Status

SCSI Bus 0 (0x00)
SCSIID 5 (0x05)
Block Size 512 Bytes Per Block (0x0200)
Total Blocks 146.8 GB (0x11175330)
Reserved Blocks 0x00000440
Drive Model COMPAQ BF1468A4B3
Drive Serial Number JAX0XXVJ
Drive Firmware Revision HPB5
SCSI Inquiry Bits 0x3a
Compaq Drive Stamped Stamped For Monitoring (0x01)
Last Failure Reason Hot Removed (0x14)
Device Flags 0xcd
Position Device Flag Status
-------- ----------------------------- -------------
0 Drive Present And Operational Informational
2 Wide SCSI Transfers Enabled Informational
3 Synchronous Transfers Enabled Informational
6 Ultra SCSI Transfers Enabled Informational
7 Ultra2 SCSI Transfers Enabled Informational

More Device Flags 0x25
Position Device Flag Status
-------- ------------------------------------- -------------
0 SMART Predictive Failure Supported Informational
2 SMART Predictive Failure Is Enabled Informational
4 Device Attached To Internal Connector Informational
5 Configured Data Drive Informational

SCSI Lun 0x00
Yet More Device Flags 0x95
Position Device Flag Status
-------- --------------------------------------- -------------
0 DT Clocking Mode Informational
2 DT And ST Clocking Supported Informational
4 Supports Packetized SCSI Informational
7 Drive Write Cache Setting Is Changeable Informational

Even More Device Flags 0x05
Position Device Flag Status
-------- ------------------------- -------------
0 QAS Is Supported Informational
2 SCSI Arbitration Fairness Informational

Spi Speed Rules 0xf8b70800
Physical Port J1
Physical Box 0 (0x00)
Physical Bay 5 (0x05)
RPM 15000 RPM (0x00003a98)
Device Type Parallel (0x00)
SATA Version 0x00
Big Total Block Count 0x0000000000000000
RIS Starting LBA 0x0000000000000000
RIS Size 0 MB (0x00000000)
WWID All Zeroes (20 x [0x00])
Controller PHY Map All Zeroes (32 x [0x00])
PHY Count 0 (0x0000)
PHY Connected Device Type All Zeroes (256 x [0x00])
PHY To Drive Bay Number All Zeroes (256 x [0x00])
PHY To Attached Device Index All Zeroes (256 x [0x0000])
Box Index 0 (0x00)
MSA Support 0x00
Extra Device Flags 0x0000
Negotiated Link Rate All Zeroes (256 x [0x00])
Phy To Phy Map All Zeroes (256 x [0x00])
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Multi LUN Device LUN Count 0x00
Minimum Good Firmware Revision empty
Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00])
Current Temperature 0x00
Temperature Threshold 0x00
Maximum Temperature 0x00
Logical Blocks Per Physical Block 0x00
Current Q Depth Limit 0x0000
Switch Name All Zeroes (10 x [0x00])
Switch Port 0x0000
Alternate Paths Switch Name All Zeroes (40 x [0x00])
Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Power On Hours 0x0000
Percent Endurance Used 0x0000
Drive Authentication 0x00
Smart Carrier Authentication 0x00
Smart Carrier Application Version 0x00
Smart Carrier Bootloader Version 0x00

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Factory)

Serial Number JAX0XXVJ
Firmware Revision HPB5
Product Revision COMPAQ BF1468A4B3
Reference Time 0x003abac7
Sectors Read 0x0000003f3d6b63ea
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x00000002740547f4
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Reset)

Serial Number JAX0XXVJ
Firmware Revision HPB5
Product Revision COMPAQ BF1468A4B3
Reference Time 0x000000ad
Sectors Read 0x0000000012e07c07
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x000000000000019c
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000000
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Violations

Threshold Violation Flags All Zeroes (256 x [0x00])
Offset To Extended Threshold Violation Flags 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
Total Structure Length 0 (0x00000000)
Fixed Structure Length 0 (0x00000000)

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Parameter Control

Serial Number 0x8054
Firmware Revision 0x8248
Product Revision 0x8268
Reference Time 0x8184
Sectors Read 0x8108
Read Errors Hard 0x8184
Read Errors Retry Recovered 0x8184
Read Errors ECC Corrected 0x8188
Sectors Written 0x8108
Write Errors Hard 0x8184
Write Errors Retry Recovered 0x8184
Seek Count 33032 (0x8108)
Seek Errors 0x8188
Spin Cycles 0x8184
Spin Up Time 0x8a82
Performance Test 1 0x0a82
Performance Test 2 0x8a82
Performance Test 3 0x8a82
Performance Test 4 0x8a82
Reallocation Sects 0x0a04
Reallocated Sects 0x8d84
DRQ Timeouts 0x0982
Other Timeouts 0x0182
Drive Rebuild Count 386 (0x0182)
Spin Retries 2434 (0x0982)
Recovers Failed Read 0x8182
Recovers Failed Write 0x0182
Format Errors 0x0182
Self Test Failures 0x0982
Not Ready Failures 0x0184
Remap Abort Failures 0x0984
IRQ Deglitch Count 0x0984
Bus Faults 33156 (0x8184)
Hot Plug Count 0x0184
Track Rewrite Errors 0x0982
Write Errors After Remap 0x0982
Background Firmware Revision 0x0a48
Media Failures 0x0182
Hardware Errors 0x0182
Aborted Command Failures 0x0182
Spin Up Failures 0x0182
Bad Target Count 386 (0x0182)
Predictive Failure Errors 0x2184

800 ₽
800 ₽
BF1468A4B3, no warnings, no errors

Комплектация:
HDD HP BF14689BC5, Part# : 365699-009 (CN: 29BC501CXSS01K)
Салазки HP Spare 404712-001
Тест поверхности:
Сектор начала тестирования: 0
Сектор конца тестирования: 286 734 239
Протестировано от общего объема в %: 100
Результаты сканирования: no warnings, no errors
Подробнее смотри скриншот результатов проверки Victoria 4.47

--------- ADUReaport.txt ---------
Time Generated: Friday December 09, 2016 10:22:30AM

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Physical Drive Status

SCSI Bus 0 (0x00)
SCSIID 3 (0x03)
Block Size 512 Bytes Per Block (0x0200)
Total Blocks 146.8 GB (0x11175330)
Reserved Blocks 0x00000440
Drive Model COMPAQ BF14689BC5
Drive Serial Number DN01P62011F90605
Drive Firmware Revision HPB1
SCSI Inquiry Bits 0x3a
Compaq Drive Stamped Stamped For Monitoring (0x01)
Last Failure Reason Timeout (0x07)
Device Flags 0xcd
Position Device Flag Status
-------- ----------------------------- -------------
0 Drive Present And Operational Informational
2 Wide SCSI Transfers Enabled Informational
3 Synchronous Transfers Enabled Informational
6 Ultra SCSI Transfers Enabled Informational
7 Ultra2 SCSI Transfers Enabled Informational

More Device Flags 0x25
Position Device Flag Status
-------- ------------------------------------- -------------
0 SMART Predictive Failure Supported Informational
2 SMART Predictive Failure Is Enabled Informational
4 Device Attached To Internal Connector Informational
5 Configured Data Drive Informational

SCSI Lun 0x00
Yet More Device Flags 0x9d
Position Device Flag Status
-------- --------------------------------------- -------------
0 DT Clocking Mode Informational
2 DT And ST Clocking Supported Informational
3 U320 Transfers Enabled Informational
4 Supports Packetized SCSI Informational
7 Drive Write Cache Setting Is Changeable Informational

Even More Device Flags 0x05
Position Device Flag Status
-------- ------------------------- -------------
0 QAS Is Supported Informational
2 SCSI Arbitration Fairness Informational

Spi Speed Rules 0xf8b70800
Physical Port J1
Physical Box 0 (0x00)
Physical Bay 3 (0x03)
RPM 15000 RPM (0x00003a98)
Device Type Parallel (0x00)
SATA Version 0x00
Big Total Block Count 0x0000000000000000
RIS Starting LBA 0x0000000000000000
RIS Size 0 MB (0x00000000)
WWID All Zeroes (20 x [0x00])
Controller PHY Map All Zeroes (32 x [0x00])
PHY Count 0 (0x0000)
PHY Connected Device Type All Zeroes (256 x [0x00])
PHY To Drive Bay Number All Zeroes (256 x [0x00])
PHY To Attached Device Index All Zeroes (256 x [0x0000])
Box Index 0 (0x00)
MSA Support 0x00
Extra Device Flags 0x0000
Negotiated Link Rate All Zeroes (256 x [0x00])
Phy To Phy Map All Zeroes (256 x [0x00])
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Multi LUN Device LUN Count 0x00
Minimum Good Firmware Revision empty
Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00])
Current Temperature 0x00
Temperature Threshold 0x00
Maximum Temperature 0x00
Logical Blocks Per Physical Block 0x00
Current Q Depth Limit 0x0000
Switch Name All Zeroes (10 x [0x00])
Switch Port 0x0000
Alternate Paths Switch Name All Zeroes (40 x [0x00])
Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Power On Hours 0x0000
Percent Endurance Used 0x0000
Drive Authentication 0x00
Smart Carrier Authentication 0x00
Smart Carrier Application Version 0x00
Smart Carrier Bootloader Version 0x00

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Factory)

Serial Number DN01P62011F90605
Firmware Revision HPB1
Product Revision COMPAQ BF14689BC5
Reference Time 0x0042bae2
Sectors Read 0x0000009c738126ba
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x00000012486bc437
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0024
Drive Rebuild Count 1 (0x0001)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Reset)

Serial Number DN01P62011F90605
Firmware Revision HPB1
Product Revision COMPAQ BF14689BC5
Reference Time 0x00000047
Sectors Read 0x00000000111738bd
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x0000000000000650
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0x00a2
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Violations

Threshold Violation Flags All Zeroes (256 x [0x00])
Offset To Extended Threshold Violation Flags 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
Total Structure Length 0 (0x00000000)
Fixed Structure Length 0 (0x00000000)

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Parameter Control

Serial Number 0x8054
Firmware Revision 0x8248
Product Revision 0x8268
Reference Time 0x8184
Sectors Read 0x8108
Read Errors Hard 0x8184
Read Errors Retry Recovered 0x8184
Read Errors ECC Corrected 0x8188
Sectors Written 0x8108
Write Errors Hard 0x8184
Write Errors Retry Recovered 0x8184
Seek Count 33032 (0x8108)
Seek Errors 0x8188
Spin Cycles 0x8184
Spin Up Time 0x8a82
Performance Test 1 0x0a82
Performance Test 2 0x8a82
Performance Test 3 0x8a82
Performance Test 4 0x8a82
Reallocation Sects 0x0a04
Reallocated Sects 0x8d84
DRQ Timeouts 0x0982
Other Timeouts 0x0182
Drive Rebuild Count 386 (0x0182)
Spin Retries 2434 (0x0982)
Recovers Failed Read 0x8182
Recovers Failed Write 0x0182
Format Errors 0x0182
Self Test Failures 0x0982
Not Ready Failures 0x0184
Remap Abort Failures 0x0984
IRQ Deglitch Count 0x0984
Bus Faults 33156 (0x8184)
Hot Plug Count 0x0184
Track Rewrite Errors 0x0982
Write Errors After Remap 0x0982
Background Firmware Revision 0x0a48
Media Failures 0x0182
Hardware Errors 0x0182
Aborted Command Failures 0x0182
Spin Up Failures 0x0182
Bad Target Count 386 (0x0182)
Predictive Failure Errors 0x2184

800 ₽
800 ₽
BF14689BC5, no warnings, no errors

Комплектация:
HDD HP BF1468A4CC, P/N: 360209-011 (CT:2A4CC016CSE3XXJ)
Салазки HP Spare 347779-001

Тест поверхности:
Сектор начала тестирования: 0
Сектор конца тестирования: 286 734 239
Протестировано от общего объема в %: 100
Результаты сканирования: no warnings, no errors
Подробнее смотри скриншот результатов проверки Victoria 4.47

--------- ADUReaport.txt ---------
Time Generated: Friday December 09, 2016 10:22:30AM


Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Physical Drive Status

SCSI Bus 0 (0x00)
SCSIID 4 (0x04)
Block Size 512 Bytes Per Block (0x0200)
Total Blocks 146.8 GB (0x11175330)
Reserved Blocks 0x00000440
Drive Model COMPAQ BF1468A4CC
Drive Serial Number 3KN0R9EF00007618V85Z
Drive Firmware Revision HPB5
SCSI Inquiry Bits 0x3e
Compaq Drive Stamped Stamped For Monitoring (0x01)
Last Failure Reason Hot Plug Start Unit Failed (0x1c)
Device Flags 0xcd
Position Device Flag Status
-------- ----------------------------- -------------
0 Drive Present And Operational Informational
2 Wide SCSI Transfers Enabled Informational
3 Synchronous Transfers Enabled Informational
6 Ultra SCSI Transfers Enabled Informational
7 Ultra2 SCSI Transfers Enabled Informational

More Device Flags 0x25
Position Device Flag Status
-------- ------------------------------------- -------------
0 SMART Predictive Failure Supported Informational
2 SMART Predictive Failure Is Enabled Informational
4 Device Attached To Internal Connector Informational
5 Configured Data Drive Informational

SCSI Lun 0x00
Yet More Device Flags 0x9d
Position Device Flag Status
-------- --------------------------------------- -------------
0 DT Clocking Mode Informational
2 DT And ST Clocking Supported Informational
3 U320 Transfers Enabled Informational
4 Supports Packetized SCSI Informational
7 Drive Write Cache Setting Is Changeable Informational

Even More Device Flags 0x05
Position Device Flag Status
-------- ------------------------- -------------
0 QAS Is Supported Informational
2 SCSI Arbitration Fairness Informational

Spi Speed Rules 0xf8b70800
Physical Port J1
Physical Box 0 (0x00)
Physical Bay 4 (0x04)
RPM 15000 RPM (0x00003aa7)
Device Type Parallel (0x00)
SATA Version 0x00
Big Total Block Count 0x0000000000000000
RIS Starting LBA 0x0000000000000000
RIS Size 0 MB (0x00000000)
WWID All Zeroes (20 x [0x00])
Controller PHY Map All Zeroes (32 x [0x00])
PHY Count 0 (0x0000)
PHY Connected Device Type All Zeroes (256 x [0x00])
PHY To Drive Bay Number All Zeroes (256 x [0x00])
PHY To Attached Device Index All Zeroes (256 x [0x0000])
Box Index 0 (0x00)
MSA Support 0x00
Extra Device Flags 0x0000
Negotiated Link Rate All Zeroes (256 x [0x00])
Phy To Phy Map All Zeroes (256 x [0x00])
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Multi LUN Device LUN Count 0x00
Minimum Good Firmware Revision empty
Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00])
Current Temperature 0x00
Temperature Threshold 0x00
Maximum Temperature 0x00
Logical Blocks Per Physical Block 0x00
Current Q Depth Limit 0x0000
Switch Name All Zeroes (10 x [0x00])
Switch Port 0x0000
Alternate Paths Switch Name All Zeroes (40 x [0x00])
Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Power On Hours 0x0000
Percent Endurance Used 0x0000
Drive Authentication 0x00
Smart Carrier Authentication 0x00
Smart Carrier Application Version 0x00
Smart Carrier Bootloader Version 0x00

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Factory)

Serial Number 3KN0R9EF00007618V85Z
Firmware Revision HPB5
Product Revision COMPAQ BF1468A4CC
Reference Time 0x004005f3
Sectors Read 0x0000008bf9c37678
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000006
Sectors Written 0x00000011778acb74
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000002
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Reset)

Serial Number 3KN0R9EF00007618V85Z
Firmware Revision HPB5
Product Revision COMPAQ BF1468A4CC
Reference Time 0x00000044
Sectors Read 0x0000000011173806
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x0000000000000454
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0x00a3
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Violations

Threshold Violation Flags All Zeroes (256 x [0x00])
Offset To Extended Threshold Violation Flags 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
Total Structure Length 0 (0x00000000)
Fixed Structure Length 0 (0x00000000)

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Parameter Control

Serial Number 0x8054
Firmware Revision 0x8248
Product Revision 0x8268
Reference Time 0x8184
Sectors Read 0x8108
Read Errors Hard 0x8184
Read Errors Retry Recovered 0x8184
Read Errors ECC Corrected 0x8188
Sectors Written 0x8108
Write Errors Hard 0x8184
Write Errors Retry Recovered 0x8184
Seek Count 33032 (0x8108)
Seek Errors 0x8188
Spin Cycles 0x8184
Spin Up Time 0x8a82
Performance Test 1 0x0a82
Performance Test 2 0x8a82
Performance Test 3 0x8a82
Performance Test 4 0x8a82
Reallocation Sects 0x0a04
Reallocated Sects 0x8d84
DRQ Timeouts 0x0982
Other Timeouts 0x0182
Drive Rebuild Count 386 (0x0182)
Spin Retries 2434 (0x0982)
Recovers Failed Read 0x8182
Recovers Failed Write 0x0182
Format Errors 0x0182
Self Test Failures 0x0982
Not Ready Failures 0x0184
Remap Abort Failures 0x0984
IRQ Deglitch Count 0x0984
Bus Faults 33156 (0x8184)
Hot Plug Count 0x0184
Track Rewrite Errors 0x0982
Write Errors After Remap 0x0982
Background Firmware Revision 0x0a48
Media Failures 0x0182
Hardware Errors 0x0182
Aborted Command Failures 0x0182
Spin Up Failures 0x0182
Bad Target Count 386 (0x0182)
Predictive Failure Errors 0x2184

800 ₽
800 ₽
BF1468A4CC, no warnings, no errors

Комплектация:
HDD HP BF1468A4B3, P/N: 321499-006 (CT: 24AB3013ST40AB)
Салазки HP Spare 404712-001
Тест поверхности:
Сектор начала тестирования: 0
Сектор конца тестирования: 286 734 239
Протестировано от общего объема в %: 100
Результаты сканирования: no warnings, no errors
Подробнее смотри скриншот результатов проверки Victoria 4.47

--------- ADUReaport.txt ---------
Time Generated: Friday December 09, 2016 10:22:30AM


Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Physical Drive Status

SCSI Bus 0 (0x00)
SCSIID 5 (0x05)
Block Size 512 Bytes Per Block (0x0200)
Total Blocks 146.8 GB (0x11175330)
Reserved Blocks 0x00000440
Drive Model COMPAQ BF1468A4B3
Drive Serial Number JAX3H36J
Drive Firmware Revision HPB5
SCSI Inquiry Bits 0x3a
Compaq Drive Stamped Stamped For Monitoring (0x01)
Last Failure Reason Hot Removed (0x14)
Device Flags 0xcd
Position Device Flag Status
-------- ----------------------------- -------------
0 Drive Present And Operational Informational
2 Wide SCSI Transfers Enabled Informational
3 Synchronous Transfers Enabled Informational
6 Ultra SCSI Transfers Enabled Informational
7 Ultra2 SCSI Transfers Enabled Informational

More Device Flags 0x25
Position Device Flag Status
-------- ------------------------------------- -------------
0 SMART Predictive Failure Supported Informational
2 SMART Predictive Failure Is Enabled Informational
4 Device Attached To Internal Connector Informational
5 Configured Data Drive Informational

SCSI Lun 0x00
Yet More Device Flags 0x9d
Position Device Flag Status
-------- --------------------------------------- -------------
0 DT Clocking Mode Informational
2 DT And ST Clocking Supported Informational
3 U320 Transfers Enabled Informational
4 Supports Packetized SCSI Informational
7 Drive Write Cache Setting Is Changeable Informational

Even More Device Flags 0x05
Position Device Flag Status
-------- ------------------------- -------------
0 QAS Is Supported Informational
2 SCSI Arbitration Fairness Informational

Spi Speed Rules 0xf8b70800
Physical Port J1
Physical Box 0 (0x00)
Physical Bay 5 (0x05)
RPM 15000 RPM (0x00003a98)
Device Type Parallel (0x00)
SATA Version 0x00
Big Total Block Count 0x0000000000000000
RIS Starting LBA 0x0000000000000000
RIS Size 0 MB (0x00000000)
WWID All Zeroes (20 x [0x00])
Controller PHY Map All Zeroes (32 x [0x00])
PHY Count 0 (0x0000)
PHY Connected Device Type All Zeroes (256 x [0x00])
PHY To Drive Bay Number All Zeroes (256 x [0x00])
PHY To Attached Device Index All Zeroes (256 x [0x0000])
Box Index 0 (0x00)
MSA Support 0x00
Extra Device Flags 0x0000
Negotiated Link Rate All Zeroes (256 x [0x00])
Phy To Phy Map All Zeroes (256 x [0x00])
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Multi LUN Device LUN Count 0x00
Minimum Good Firmware Revision empty
Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00])
Current Temperature 0x00
Temperature Threshold 0x00
Maximum Temperature 0x00
Logical Blocks Per Physical Block 0x00
Current Q Depth Limit 0x0000
Switch Name All Zeroes (10 x [0x00])
Switch Port 0x0000
Alternate Paths Switch Name All Zeroes (40 x [0x00])
Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Power On Hours 0x0000
Percent Endurance Used 0x0000
Drive Authentication 0x00
Smart Carrier Authentication 0x00
Smart Carrier Application Version 0x00
Smart Carrier Bootloader Version 0x00

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Factory)

Serial Number JAX3H36J
Firmware Revision HPB5
Product Revision COMPAQ BF1468A4B3
Reference Time 0x003aba5c
Sectors Read 0x0000003f5ba4fa05
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x000000028292e125
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Reset)

Serial Number JAX3H36J
Firmware Revision HPB5
Product Revision COMPAQ BF1468A4B3
Reference Time 0x00000047
Sectors Read 0x000000001117381f
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x00000000000002cd
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0x00aa
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Violations

Threshold Violation Flags All Zeroes (256 x [0x00])
Offset To Extended Threshold Violation Flags 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
Total Structure Length 0 (0x00000000)
Fixed Structure Length 0 (0x00000000)

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Parameter Control

Serial Number 0x8054
Firmware Revision 0x8248
Product Revision 0x8268
Reference Time 0x8184
Sectors Read 0x8108
Read Errors Hard 0x8184
Read Errors Retry Recovered 0x8184
Read Errors ECC Corrected 0x8188
Sectors Written 0x8108
Write Errors Hard 0x8184
Write Errors Retry Recovered 0x8184
Seek Count 33032 (0x8108)
Seek Errors 0x8188
Spin Cycles 0x8184
Spin Up Time 0x8a82
Performance Test 1 0x0a82
Performance Test 2 0x8a82
Performance Test 3 0x8a82
Performance Test 4 0x8a82
Reallocation Sects 0x0a04
Reallocated Sects 0x8d84
DRQ Timeouts 0x0982
Other Timeouts 0x0182
Drive Rebuild Count 386 (0x0182)
Spin Retries 2434 (0x0982)
Recovers Failed Read 0x8182
Recovers Failed Write 0x0182
Format Errors 0x0182
Self Test Failures 0x0982
Not Ready Failures 0x0184
Remap Abort Failures 0x0984
IRQ Deglitch Count 0x0984
Bus Faults 33156 (0x8184)
Hot Plug Count 0x0184
Track Rewrite Errors 0x0982
Write Errors After Remap 0x0982
Background Firmware Revision 0x0a48
Media Failures 0x0182
Hardware Errors 0x0182
Aborted Command Failures 0x0182
Spin Up Failures 0x0182
Bad Target Count 386 (0x0182)
Predictive Failure Errors 0x2184

800 ₽
800 ₽
BF1468A4B3, no warnings, no errors

Комплектация:
HDD HP BF1468A4BB, P/N: 356914-009 (CT: 2A4BB01H1STOYG)
Салазки HP Spare 404712-001

Тест поверхности:
Сектор начала тестирования: 0
Сектор конца тестирования: 286 734 239
Протестировано от общего объема в %: 100
Результаты сканирования: no warnings, no errors
Подробнее смотри скриншот результатов проверки Victoria 4.47

--------- ADUReaport.txt ---------
Time Generated: Friday December 09, 2016 2:25:24PM

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Physical Drive Status

SCSI Bus 0 (0x00)
SCSIID 4 (0x04)
Block Size 512 Bytes Per Block (0x0200)
Total Blocks 146.8 GB (0x11175330)
Reserved Blocks 0x00000440
Drive Model COMPAQ BF1468A4BB
Drive Serial Number K805DY7K
Drive Firmware Revision HPB9
SCSI Inquiry Bits 0x3e
Compaq Drive Stamped Stamped For Monitoring (0x01)
Last Failure Reason Hot Plug Start Unit Failed (0x1c)
Device Flags 0xcd
Position Device Flag Status
-------- ----------------------------- -------------
0 Drive Present And Operational Informational
2 Wide SCSI Transfers Enabled Informational
3 Synchronous Transfers Enabled Informational
6 Ultra SCSI Transfers Enabled Informational
7 Ultra2 SCSI Transfers Enabled Informational

More Device Flags 0x25
Position Device Flag Status
-------- ------------------------------------- -------------
0 SMART Predictive Failure Supported Informational
2 SMART Predictive Failure Is Enabled Informational
4 Device Attached To Internal Connector Informational
5 Configured Data Drive Informational

SCSI Lun 0x00
Yet More Device Flags 0x9d
Position Device Flag Status
-------- --------------------------------------- -------------
0 DT Clocking Mode Informational
2 DT And ST Clocking Supported Informational
3 U320 Transfers Enabled Informational
4 Supports Packetized SCSI Informational
7 Drive Write Cache Setting Is Changeable Informational

Even More Device Flags 0x05
Position Device Flag Status
-------- ------------------------- -------------
0 QAS Is Supported Informational
2 SCSI Arbitration Fairness Informational

Spi Speed Rules 0xf8b70800
Physical Port J1
Physical Box 0 (0x00)
Physical Bay 4 (0x04)
RPM 15000 RPM (0x00003aa8)
Device Type Parallel (0x00)
SATA Version 0x00
Big Total Block Count 0x0000000000000000
RIS Starting LBA 0x0000000000000000
RIS Size 0 MB (0x00000000)
WWID All Zeroes (20 x [0x00])
Controller PHY Map All Zeroes (32 x [0x00])
PHY Count 0 (0x0000)
PHY Connected Device Type All Zeroes (256 x [0x00])
PHY To Drive Bay Number All Zeroes (256 x [0x00])
PHY To Attached Device Index All Zeroes (256 x [0x0000])
Box Index 0 (0x00)
MSA Support 0x00
Extra Device Flags 0x0000
Negotiated Link Rate All Zeroes (256 x [0x00])
Phy To Phy Map All Zeroes (256 x [0x00])
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Multi LUN Device LUN Count 0x00
Minimum Good Firmware Revision empty
Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00])
Current Temperature 0x00
Temperature Threshold 0x00
Maximum Temperature 0x00
Logical Blocks Per Physical Block 0x00
Current Q Depth Limit 0x0000
Switch Name All Zeroes (10 x [0x00])
Switch Port 0x0000
Alternate Paths Switch Name All Zeroes (40 x [0x00])
Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Power On Hours 0x0000
Percent Endurance Used 0x0000
Drive Authentication 0x00
Smart Carrier Authentication 0x00
Smart Carrier Application Version 0x00
Smart Carrier Bootloader Version 0x00

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Factory)

Serial Number K805DY7K
Firmware Revision HPB4
Product Revision COMPAQ BF1468A4BB
Reference Time 0x0042c976
Sectors Read 0x0000009c9d54bb91
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000007
Read Errors ECC Corrected 0x000000000000000d
Sectors Written 0x0000001257df8759
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x00fa
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Reset)

Serial Number K805DY7K
Firmware Revision HPB9
Product Revision COMPAQ BF1468A4BB
Reference Time 0x000000e5
Sectors Read 0x0000000011173e77
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x0000000000000474
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000000
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Violations

Threshold Violation Flags All Zeroes (256 x [0x00])
Offset To Extended Threshold Violation Flags 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
Total Structure Length 0 (0x00000000)
Fixed Structure Length 0 (0x00000000)

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Parameter Control

Serial Number 0x8054
Firmware Revision 0x8248
Product Revision 0x8268
Reference Time 0x8184
Sectors Read 0x8108
Read Errors Hard 0x8184
Read Errors Retry Recovered 0x8184
Read Errors ECC Corrected 0x8188
Sectors Written 0x8108
Write Errors Hard 0x8184
Write Errors Retry Recovered 0x8184
Seek Count 33032 (0x8108)
Seek Errors 0x8188
Spin Cycles 0x8184
Spin Up Time 0x8a82
Performance Test 1 0x0a82
Performance Test 2 0x8a82
Performance Test 3 0x8a82
Performance Test 4 0x8a82
Reallocation Sects 0x0a04
Reallocated Sects 0x8d84
DRQ Timeouts 0x0982
Other Timeouts 0x0182
Drive Rebuild Count 386 (0x0182)
Spin Retries 2434 (0x0982)
Recovers Failed Read 0x8182
Recovers Failed Write 0x0182
Format Errors 0x0182
Self Test Failures 0x0982
Not Ready Failures 0x0184
Remap Abort Failures 0x0984
IRQ Deglitch Count 0x0984
Bus Faults 33156 (0x8184)
Hot Plug Count 0x0184
Track Rewrite Errors 0x0982
Write Errors After Remap 0x0982
Background Firmware Revision 0x0a48
Media Failures 0x0182
Hardware Errors 0x0182
Aborted Command Failures 0x0182
Spin Up Failures 0x0182
Bad Target Count 386 (0x0182)
Predictive Failure Errors 0x2184

800 ₽
800 ₽
BF1468A4BB, no warnings, no errors

Комплектация:
HDD HP BF14688286, P/N: 360209-005 (CT:28286016CRH9JJ)
Салазки HP Spare ХХХХХ-ХХХ

Тест поверхности:
Сектор начала тестирования: 0
Сектор конца тестирования: 2286 734 239
Протестировано от общего объема в %: 100
Результаты сканирования: no warnings, no errors
Подробнее смотри скриншот результатов проверки Victoria 4.47

--------- ADUReaport.txt ---------
Time Generated: Friday December 09, 2016 3:48:25PM


Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Physical Drive Status

SCSI Bus 0 (0x00)
SCSIID 5 (0x05)
Block Size 512 Bytes Per Block (0x0200)
Total Blocks 146.8 GB (0x11175330)
Reserved Blocks 0x00000440
Drive Model COMPAQ BF14688286
Drive Serial Number 3KN055T3000075354RSJ
Drive Firmware Revision HPB3
SCSI Inquiry Bits 0x3e
Compaq Drive Stamped Stamped For Monitoring (0x01)
Last Failure Reason Bus Reset Recovery Aborted (0x13)
Device Flags 0xcd
Position Device Flag Status
-------- ----------------------------- -------------
0 Drive Present And Operational Informational
2 Wide SCSI Transfers Enabled Informational
3 Synchronous Transfers Enabled Informational
6 Ultra SCSI Transfers Enabled Informational
7 Ultra2 SCSI Transfers Enabled Informational

More Device Flags 0x25
Position Device Flag Status
-------- ------------------------------------- -------------
0 SMART Predictive Failure Supported Informational
2 SMART Predictive Failure Is Enabled Informational
4 Device Attached To Internal Connector Informational
5 Configured Data Drive Informational

SCSI Lun 0x00
Yet More Device Flags 0x9d
Position Device Flag Status
-------- --------------------------------------- -------------
0 DT Clocking Mode Informational
2 DT And ST Clocking Supported Informational
3 U320 Transfers Enabled Informational
4 Supports Packetized SCSI Informational
7 Drive Write Cache Setting Is Changeable Informational

Even More Device Flags 0x05
Position Device Flag Status
-------- ------------------------- -------------
0 QAS Is Supported Informational
2 SCSI Arbitration Fairness Informational

Spi Speed Rules 0xf8b70800
Physical Port J1
Physical Box 0 (0x00)
Physical Bay 5 (0x05)
RPM 15000 RPM (0x00003aa7)
Device Type Parallel (0x00)
SATA Version 0x00
Big Total Block Count 0x0000000000000000
RIS Starting LBA 0x0000000000000000
RIS Size 0 MB (0x00000000)
WWID All Zeroes (20 x [0x00])
Controller PHY Map All Zeroes (32 x [0x00])
PHY Count 0 (0x0000)
PHY Connected Device Type All Zeroes (256 x [0x00])
PHY To Drive Bay Number All Zeroes (256 x [0x00])
PHY To Attached Device Index All Zeroes (256 x [0x0000])
Box Index 0 (0x00)
MSA Support 0x00
Extra Device Flags 0x0000
Negotiated Link Rate All Zeroes (256 x [0x00])
Phy To Phy Map All Zeroes (256 x [0x00])
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Multi LUN Device LUN Count 0x00
Minimum Good Firmware Revision empty
Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00])
Current Temperature 0x00
Temperature Threshold 0x00
Maximum Temperature 0x00
Logical Blocks Per Physical Block 0x00
Current Q Depth Limit 0x0000
Switch Name All Zeroes (10 x [0x00])
Switch Port 0x0000
Alternate Paths Switch Name All Zeroes (40 x [0x00])
Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Power On Hours 0x0000
Percent Endurance Used 0x0000
Drive Authentication 0x00
Smart Carrier Authentication 0x00
Smart Carrier Application Version 0x00
Smart Carrier Bootloader Version 0x00

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Factory)

Serial Number 3KN055T3000075354RSJ
Firmware Revision HPB2
Product Revision COMPAQ BF14688286
Reference Time 0x0050f769
Sectors Read 0x000000aa729375fe
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x0000001bac358cf7
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000001
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Reset)

Serial Number 3KN055T3000075354RSJ
Firmware Revision HPB3
Product Revision COMPAQ BF14688286
Reference Time 0x00000048
Sectors Read 0x0000000011173801
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x00000000000001fc
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0x00ad
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Violations

Threshold Violation Flags All Zeroes (256 x [0x00])
Offset To Extended Threshold Violation Flags 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
Total Structure Length 0 (0x00000000)
Fixed Structure Length 0 (0x00000000)

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Parameter Control

Serial Number 0x8054
Firmware Revision 0x8248
Product Revision 0x8268
Reference Time 0x8184
Sectors Read 0x8108
Read Errors Hard 0x8184
Read Errors Retry Recovered 0x8184
Read Errors ECC Corrected 0x8188
Sectors Written 0x8108
Write Errors Hard 0x8184
Write Errors Retry Recovered 0x8184
Seek Count 33032 (0x8108)
Seek Errors 0x8188
Spin Cycles 0x8184
Spin Up Time 0x8a82
Performance Test 1 0x0a82
Performance Test 2 0x8a82
Performance Test 3 0x8a82
Performance Test 4 0x8a82
Reallocation Sects 0x0a04
Reallocated Sects 0x8d84
DRQ Timeouts 0x0982
Other Timeouts 0x0182
Drive Rebuild Count 386 (0x0182)
Spin Retries 2434 (0x0982)
Recovers Failed Read 0x8182
Recovers Failed Write 0x0182
Format Errors 0x0182
Self Test Failures 0x0982
Not Ready Failures 0x0184
Remap Abort Failures 0x0984
IRQ Deglitch Count 0x0984
Bus Faults 33156 (0x8184)
Hot Plug Count 0x0184
Track Rewrite Errors 0x0982
Write Errors After Remap 0x0982
Background Firmware Revision 0x0a48
Media Failures 0x0182
Hardware Errors 0x0182
Aborted Command Failures 0x0182
Spin Up Failures 0x0182
Bad Target Count 386 (0x0182)
Predictive Failure Errors 0x2184

800 ₽
800 ₽
BF14688286, no warnings, no errors

Комплектация:
HDD HP BF14689BC5, Part# : 365699-009 (CT: 29BC501CXVH01J)
Салазки HP Spare 404712-001

Тест поверхности:
Сектор начала тестирования: 0
Сектор конца тестирования: 286 734 239
Протестировано от общего объема в %: 100
Результаты сканирования: no warnings, no errors
Подробнее смотри скриншот результатов проверки Victoria 4.47

--------- ADUReaport.txt ---------
Time Generated: Friday December 09, 2016 3:48:25PM

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Physical Drive Status

SCSI Bus 0 (0x00)
SCSIID 4 (0x04)
Block Size 512 Bytes Per Block (0x0200)
Total Blocks 146.8 GB (0x11175330)
Reserved Blocks 0x00000440
Drive Model COMPAQ BF14689BC5
Drive Serial Number DN01P7C08JAT0750
Drive Firmware Revision HPB1
SCSI Inquiry Bits 0x3a
Compaq Drive Stamped Stamped For Monitoring (0x01)
Last Failure Reason Hot Removed (0x14)
Device Flags 0xcd
Position Device Flag Status
-------- ----------------------------- -------------
0 Drive Present And Operational Informational
2 Wide SCSI Transfers Enabled Informational
3 Synchronous Transfers Enabled Informational
6 Ultra SCSI Transfers Enabled Informational
7 Ultra2 SCSI Transfers Enabled Informational

More Device Flags 0x25
Position Device Flag Status
-------- ------------------------------------- -------------
0 SMART Predictive Failure Supported Informational
2 SMART Predictive Failure Is Enabled Informational
4 Device Attached To Internal Connector Informational
5 Configured Data Drive Informational

SCSI Lun 0x00
Yet More Device Flags 0x9d
Position Device Flag Status
-------- --------------------------------------- -------------
0 DT Clocking Mode Informational
2 DT And ST Clocking Supported Informational
3 U320 Transfers Enabled Informational
4 Supports Packetized SCSI Informational
7 Drive Write Cache Setting Is Changeable Informational

Even More Device Flags 0x05
Position Device Flag Status
-------- ------------------------- -------------
0 QAS Is Supported Informational
2 SCSI Arbitration Fairness Informational

Spi Speed Rules 0xf8b70800
Physical Port J1
Physical Box 0 (0x00)
Physical Bay 4 (0x04)
RPM 15000 RPM (0x00003a98)
Device Type Parallel (0x00)
SATA Version 0x00
Big Total Block Count 0x0000000000000000
RIS Starting LBA 0x0000000000000000
RIS Size 0 MB (0x00000000)
WWID All Zeroes (20 x [0x00])
Controller PHY Map All Zeroes (32 x [0x00])
PHY Count 0 (0x0000)
PHY Connected Device Type All Zeroes (256 x [0x00])
PHY To Drive Bay Number All Zeroes (256 x [0x00])
PHY To Attached Device Index All Zeroes (256 x [0x0000])
Box Index 0 (0x00)
MSA Support 0x00
Extra Device Flags 0x0000
Negotiated Link Rate All Zeroes (256 x [0x00])
Phy To Phy Map All Zeroes (256 x [0x00])
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Multi LUN Device LUN Count 0x00
Minimum Good Firmware Revision empty
Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00])
Current Temperature 0x00
Temperature Threshold 0x00
Maximum Temperature 0x00
Logical Blocks Per Physical Block 0x00
Current Q Depth Limit 0x0000
Switch Name All Zeroes (10 x [0x00])
Switch Port 0x0000
Alternate Paths Switch Name All Zeroes (40 x [0x00])
Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Power On Hours 0x0000
Percent Endurance Used 0x0000
Drive Authentication 0x00
Smart Carrier Authentication 0x00
Smart Carrier Application Version 0x00
Smart Carrier Bootloader Version 0x00

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Factory)

Serial Number DN01P7C08JAT0750
Firmware Revision HPB1
Product Revision COMPAQ BF14689BC5
Reference Time 0x003663c0
Sectors Read 0x0000005b79afeaca
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000002
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x0000000de234bc7a
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Reset)

Serial Number DN01P7C08JAT0750
Firmware Revision HPB1
Product Revision COMPAQ BF14689BC5
Reference Time 0x00000049
Sectors Read 0x00000000111738a0
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x00000000000003db
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0x0098
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Violations

Threshold Violation Flags All Zeroes (256 x [0x00])
Offset To Extended Threshold Violation Flags 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
Total Structure Length 0 (0x00000000)
Fixed Structure Length 0 (0x00000000)

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Parameter Control

Serial Number 0x8054
Firmware Revision 0x8248
Product Revision 0x8268
Reference Time 0x8184
Sectors Read 0x8108
Read Errors Hard 0x8184
Read Errors Retry Recovered 0x8184
Read Errors ECC Corrected 0x8188
Sectors Written 0x8108
Write Errors Hard 0x8184
Write Errors Retry Recovered 0x8184
Seek Count 33032 (0x8108)
Seek Errors 0x8188
Spin Cycles 0x8184
Spin Up Time 0x8a82
Performance Test 1 0x0a82
Performance Test 2 0x8a82
Performance Test 3 0x8a82
Performance Test 4 0x8a82
Reallocation Sects 0x0a04
Reallocated Sects 0x8d84
DRQ Timeouts 0x0982
Other Timeouts 0x0182
Drive Rebuild Count 386 (0x0182)
Spin Retries 2434 (0x0982)
Recovers Failed Read 0x8182
Recovers Failed Write 0x0182
Format Errors 0x0182
Self Test Failures 0x0982
Not Ready Failures 0x0184
Remap Abort Failures 0x0984
IRQ Deglitch Count 0x0984
Bus Faults 33156 (0x8184)
Hot Plug Count 0x0184
Track Rewrite Errors 0x0982
Write Errors After Remap 0x0982
Background Firmware Revision 0x0a48
Media Failures 0x0182
Hardware Errors 0x0182
Aborted Command Failures 0x0182
Spin Up Failures 0x0182
Bad Target Count 386 (0x0182)
Predictive Failure Errors 0x2184

800 ₽
800 ₽
BF14689BC5, no warnings, no errors

Комплектация:
HDD HP BF14689BC5, Part# : 365699-009 (CT: 29BC501CXVG154)
Салазки HP Spare 404712-001

Тест поверхности:
Сектор начала тестирования: 0
Сектор конца тестирования: 286 734 239
Протестировано от общего объема в %: 100
Результаты сканирования: no warnings, no errors
Подробнее смотри скриншот результатов проверки Victoria 4.47

--------- ADUReaport.txt ---------
Time Generated: Friday December 09, 2016 5:31:39PM


Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Physical Drive Status

SCSI Bus 0 (0x00)
SCSIID 3 (0x03)
Block Size 512 Bytes Per Block (0x0200)
Total Blocks 146.8 GB (0x11175330)
Reserved Blocks 0x00000440
Drive Model COMPAQ BF14689BC5
Drive Serial Number DN01P7C08HWN0750
Drive Firmware Revision HPB1
SCSI Inquiry Bits 0x3a
Compaq Drive Stamped Stamped For Monitoring (0x01)
Last Failure Reason Hot Removed (0x14)
Device Flags 0xcd
Position Device Flag Status
-------- ----------------------------- -------------
0 Drive Present And Operational Informational
2 Wide SCSI Transfers Enabled Informational
3 Synchronous Transfers Enabled Informational
6 Ultra SCSI Transfers Enabled Informational
7 Ultra2 SCSI Transfers Enabled Informational

More Device Flags 0x25
Position Device Flag Status
-------- ------------------------------------- -------------
0 SMART Predictive Failure Supported Informational
2 SMART Predictive Failure Is Enabled Informational
4 Device Attached To Internal Connector Informational
5 Configured Data Drive Informational

SCSI Lun 0x00
Yet More Device Flags 0x9d
Position Device Flag Status
-------- --------------------------------------- -------------
0 DT Clocking Mode Informational
2 DT And ST Clocking Supported Informational
3 U320 Transfers Enabled Informational
4 Supports Packetized SCSI Informational
7 Drive Write Cache Setting Is Changeable Informational

Even More Device Flags 0x05
Position Device Flag Status
-------- ------------------------- -------------
0 QAS Is Supported Informational
2 SCSI Arbitration Fairness Informational

Spi Speed Rules 0xf8b70800
Physical Port J1
Physical Box 0 (0x00)
Physical Bay 3 (0x03)
RPM 15000 RPM (0x00003a98)
Device Type Parallel (0x00)
SATA Version 0x00
Big Total Block Count 0x0000000000000000
RIS Starting LBA 0x0000000000000000
RIS Size 0 MB (0x00000000)
WWID All Zeroes (20 x [0x00])
Controller PHY Map All Zeroes (32 x [0x00])
PHY Count 0 (0x0000)
PHY Connected Device Type All Zeroes (256 x [0x00])
PHY To Drive Bay Number All Zeroes (256 x [0x00])
PHY To Attached Device Index All Zeroes (256 x [0x0000])
Box Index 0 (0x00)
MSA Support 0x00
Extra Device Flags 0x0000
Negotiated Link Rate All Zeroes (256 x [0x00])
Phy To Phy Map All Zeroes (256 x [0x00])
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Multi LUN Device LUN Count 0x00
Minimum Good Firmware Revision empty
Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00])
Current Temperature 0x00
Temperature Threshold 0x00
Maximum Temperature 0x00
Logical Blocks Per Physical Block 0x00
Current Q Depth Limit 0x0000
Switch Name All Zeroes (10 x [0x00])
Switch Port 0x0000
Alternate Paths Switch Name All Zeroes (40 x [0x00])
Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Power On Hours 0x0000
Percent Endurance Used 0x0000
Drive Authentication 0x00
Smart Carrier Authentication 0x00
Smart Carrier Application Version 0x00
Smart Carrier Bootloader Version 0x00

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Factory)

Serial Number DN01P7C08HWN0750
Firmware Revision HPB1
Product Revision COMPAQ BF14689BC5
Reference Time 0x0026e3a1
Sectors Read 0x00000031c9ed840c
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x000000051033e919
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000004
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0003
Drive Rebuild Count 1 (0x0001)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Reset)

Serial Number DN01P7C08HWN0750
Firmware Revision HPB1
Product Revision COMPAQ BF14689BC5
Reference Time 0x0000005e
Sectors Read 0x00000000111738bd
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x0000000000000580
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0x009a
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Violations

Threshold Violation Flags All Zeroes (256 x [0x00])
Offset To Extended Threshold Violation Flags 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
Total Structure Length 0 (0x00000000)
Fixed Structure Length 0 (0x00000000)

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Parameter Control

Serial Number 0x8054
Firmware Revision 0x8248
Product Revision 0x8268
Reference Time 0x8184
Sectors Read 0x8108
Read Errors Hard 0x8184
Read Errors Retry Recovered 0x8184
Read Errors ECC Corrected 0x8188
Sectors Written 0x8108
Write Errors Hard 0x8184
Write Errors Retry Recovered 0x8184
Seek Count 33032 (0x8108)
Seek Errors 0x8188
Spin Cycles 0x8184
Spin Up Time 0x8a82
Performance Test 1 0x0a82
Performance Test 2 0x8a82
Performance Test 3 0x8a82
Performance Test 4 0x8a82
Reallocation Sects 0x0a04
Reallocated Sects 0x8d84
DRQ Timeouts 0x0982
Other Timeouts 0x0182
Drive Rebuild Count 386 (0x0182)
Spin Retries 2434 (0x0982)
Recovers Failed Read 0x8182
Recovers Failed Write 0x0182
Format Errors 0x0182
Self Test Failures 0x0982
Not Ready Failures 0x0184
Remap Abort Failures 0x0984
IRQ Deglitch Count 0x0984
Bus Faults 33156 (0x8184)
Hot Plug Count 0x0184
Track Rewrite Errors 0x0982
Write Errors After Remap 0x0982
Background Firmware Revision 0x0a48
Media Failures 0x0182
Hardware Errors 0x0182
Aborted Command Failures 0x0182
Spin Up Failures 0x0182
Bad Target Count 386 (0x0182)
Predictive Failure Errors 0x2184

800 ₽
800 ₽
BF14689BC5, no warnings, no errors

Комплектация:
HDD HP BF14688286, P/N: 360209-005 (CT: 28286016CRHA0F)
Салазки HP Spare 347779-001

Тест поверхности:
Сектор начала тестирования: 0
Сектор конца тестирования: 286 734 239
Протестировано от общего объема в %: 100
Результаты сканирования: no warnings, no errors
Подробнее смотри скриншот результатов проверки Victoria 4.47

--------- ADUReaport.txt ---------
Time Generated: Friday December 09, 2016 5:31:39PM

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Physical Drive Status

SCSI Bus 0 (0x00)
SCSIID 2 (0x02)
Block Size 512 Bytes Per Block (0x0200)
Total Blocks 146.8 GB (0x11175330)
Reserved Blocks 0x00000440
Drive Model COMPAQ BF14688286
Drive Serial Number 3KN05M4T00007536RW02
Drive Firmware Revision HPB3
SCSI Inquiry Bits 0x3e
Compaq Drive Stamped Stamped For Monitoring (0x01)
Last Failure Reason Hot Removed (0x14)
Device Flags 0xcd
Position Device Flag Status
-------- ----------------------------- -------------
0 Drive Present And Operational Informational
2 Wide SCSI Transfers Enabled Informational
3 Synchronous Transfers Enabled Informational
6 Ultra SCSI Transfers Enabled Informational
7 Ultra2 SCSI Transfers Enabled Informational

More Device Flags 0x25
Position Device Flag Status
-------- ------------------------------------- -------------
0 SMART Predictive Failure Supported Informational
2 SMART Predictive Failure Is Enabled Informational
4 Device Attached To Internal Connector Informational
5 Configured Data Drive Informational

SCSI Lun 0x00
Yet More Device Flags 0x9d
Position Device Flag Status
-------- --------------------------------------- -------------
0 DT Clocking Mode Informational
2 DT And ST Clocking Supported Informational
3 U320 Transfers Enabled Informational
4 Supports Packetized SCSI Informational
7 Drive Write Cache Setting Is Changeable Informational

Even More Device Flags 0x05
Position Device Flag Status
-------- ------------------------- -------------
0 QAS Is Supported Informational
2 SCSI Arbitration Fairness Informational

Spi Speed Rules 0xf8b70800
Physical Port J1
Physical Box 0 (0x00)
Physical Bay 2 (0x02)
RPM 15000 RPM (0x00003aa7)
Device Type Parallel (0x00)
SATA Version 0x00
Big Total Block Count 0x0000000000000000
RIS Starting LBA 0x0000000000000000
RIS Size 0 MB (0x00000000)
WWID All Zeroes (20 x [0x00])
Controller PHY Map All Zeroes (32 x [0x00])
PHY Count 0 (0x0000)
PHY Connected Device Type All Zeroes (256 x [0x00])
PHY To Drive Bay Number All Zeroes (256 x [0x00])
PHY To Attached Device Index All Zeroes (256 x [0x0000])
Box Index 0 (0x00)
MSA Support 0x00
Extra Device Flags 0x0000
Negotiated Link Rate All Zeroes (256 x [0x00])
Phy To Phy Map All Zeroes (256 x [0x00])
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Multi LUN Device LUN Count 0x00
Minimum Good Firmware Revision empty
Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00])
Current Temperature 0x00
Temperature Threshold 0x00
Maximum Temperature 0x00
Logical Blocks Per Physical Block 0x00
Current Q Depth Limit 0x0000
Switch Name All Zeroes (10 x [0x00])
Switch Port 0x0000
Alternate Paths Switch Name All Zeroes (40 x [0x00])
Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Power On Hours 0x0000
Percent Endurance Used 0x0000
Drive Authentication 0x00
Smart Carrier Authentication 0x00
Smart Carrier Application Version 0x00
Smart Carrier Bootloader Version 0x00

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Factory)

Serial Number 3KN05M4T00007536RW02
Firmware Revision HPB2
Product Revision COMPAQ BF14688286
Reference Time 0x0050f77f
Sectors Read 0x000000ab25b62edb
Read Errors Hard 0x0000001e
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000003
Sectors Written 0x0000001b7f098883
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Reset)

Serial Number 3KN05M4T00007536RW02
Firmware Revision HPB3
Product Revision COMPAQ BF14688286
Reference Time 0x0000005e
Sectors Read 0x000000001117385a
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x0000000000000742
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0x00f1
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Violations

Threshold Violation Flags All Zeroes (256 x [0x00])
Offset To Extended Threshold Violation Flags 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
Total Structure Length 0 (0x00000000)
Fixed Structure Length 0 (0x00000000)

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Parameter Control

Serial Number 0x8054
Firmware Revision 0x8248
Product Revision 0x8268
Reference Time 0x8184
Sectors Read 0x8108
Read Errors Hard 0x8184
Read Errors Retry Recovered 0x8184
Read Errors ECC Corrected 0x8188
Sectors Written 0x8108
Write Errors Hard 0x8184
Write Errors Retry Recovered 0x8184
Seek Count 33032 (0x8108)
Seek Errors 0x8188
Spin Cycles 0x8184
Spin Up Time 0x8a82
Performance Test 1 0x0a82
Performance Test 2 0x8a82
Performance Test 3 0x8a82
Performance Test 4 0x8a82
Reallocation Sects 0x0a04
Reallocated Sects 0x8d84
DRQ Timeouts 0x0982
Other Timeouts 0x0182
Drive Rebuild Count 386 (0x0182)
Spin Retries 2434 (0x0982)
Recovers Failed Read 0x8182
Recovers Failed Write 0x0182
Format Errors 0x0182
Self Test Failures 0x0982
Not Ready Failures 0x0184
Remap Abort Failures 0x0984
IRQ Deglitch Count 0x0984
Bus Faults 33156 (0x8184)
Hot Plug Count 0x0184
Track Rewrite Errors 0x0982
Write Errors After Remap 0x0982
Background Firmware Revision 0x0a48
Media Failures 0x0182
Hardware Errors 0x0182
Aborted Command Failures 0x0182
Spin Up Failures 0x0182
Bad Target Count 386 (0x0182)
Predictive Failure Errors 0x2184

800 ₽
800 ₽
BF14688286, no warnings, no errors

Комплектация:
HDD HP BF1468B26B, P/N: 412751-015 (ST3146855LC)
Салазки HP Spare 404712-001
Тест поверхности:
Сектор начала тестирования: 0
Сектор конца тестирования: 286 374 239
Протестировано от общего объема в %: 100
Результаты сканирования: no warnings, no errors
Подробнее смотри скриншот результатов проверки Victoria 4.47

--------- ADUReaport.txt ---------
Time Generated: Friday December 09, 2016 5:31:39PM


Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Physical Drive Status

SCSI Bus 0 (0x00)
SCSIID 4 (0x04)
Block Size 512 Bytes Per Block (0x0200)
Total Blocks 146.8 GB (0x11175330)
Reserved Blocks 0x00000440
Drive Model COMPAQ BF1468B26B
Drive Serial Number 3LN4YJB000009840SPFS
Drive Firmware Revision HPB9
SCSI Inquiry Bits 0x32
Compaq Drive Stamped Stamped For Monitoring (0x01)
Last Failure Reason Hot Removed (0x14)
Device Flags 0xcd
Position Device Flag Status
-------- ----------------------------- -------------
0 Drive Present And Operational Informational
2 Wide SCSI Transfers Enabled Informational
3 Synchronous Transfers Enabled Informational
6 Ultra SCSI Transfers Enabled Informational
7 Ultra2 SCSI Transfers Enabled Informational

More Device Flags 0x25
Position Device Flag Status
-------- ------------------------------------- -------------
0 SMART Predictive Failure Supported Informational
2 SMART Predictive Failure Is Enabled Informational
4 Device Attached To Internal Connector Informational
5 Configured Data Drive Informational

SCSI Lun 0x00
Yet More Device Flags 0x9d
Position Device Flag Status
-------- --------------------------------------- -------------
0 DT Clocking Mode Informational
2 DT And ST Clocking Supported Informational
3 U320 Transfers Enabled Informational
4 Supports Packetized SCSI Informational
7 Drive Write Cache Setting Is Changeable Informational

Even More Device Flags 0x05
Position Device Flag Status
-------- ------------------------- -------------
0 QAS Is Supported Informational
2 SCSI Arbitration Fairness Informational

Spi Speed Rules 0xf8b70800
Physical Port J1
Physical Box 0 (0x00)
Physical Bay 4 (0x04)
RPM 15000 RPM (0x00003aa7)
Device Type Parallel (0x00)
SATA Version 0x00
Big Total Block Count 0x0000000000000000
RIS Starting LBA 0x0000000000000000
RIS Size 0 MB (0x00000000)
WWID All Zeroes (20 x [0x00])
Controller PHY Map All Zeroes (32 x [0x00])
PHY Count 0 (0x0000)
PHY Connected Device Type All Zeroes (256 x [0x00])
PHY To Drive Bay Number All Zeroes (256 x [0x00])
PHY To Attached Device Index All Zeroes (256 x [0x0000])
Box Index 0 (0x00)
MSA Support 0x00
Extra Device Flags 0x0000
Negotiated Link Rate All Zeroes (256 x [0x00])
Phy To Phy Map All Zeroes (256 x [0x00])
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Multi LUN Device LUN Count 0x00
Minimum Good Firmware Revision empty
Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00])
Current Temperature 0x00
Temperature Threshold 0x00
Maximum Temperature 0x00
Logical Blocks Per Physical Block 0x00
Current Q Depth Limit 0x0000
Switch Name All Zeroes (10 x [0x00])
Switch Port 0x0000
Alternate Paths Switch Name All Zeroes (40 x [0x00])
Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Power On Hours 0x0000
Percent Endurance Used 0x0000
Drive Authentication 0x00
Smart Carrier Authentication 0x00
Smart Carrier Application Version 0x00
Smart Carrier Bootloader Version 0x00

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Factory)

Serial Number 3LN4YJB000009840SPFS
Firmware Revision HPB9
Product Revision COMPAQ BF1468B26B
Reference Time 0x0037d546
Sectors Read 0x0000005f3e65cace
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x0000000e6deb327f
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000002
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Reset)

Serial Number 3LN4YJB000009840SPFS
Firmware Revision HPB9
Product Revision COMPAQ BF1468B26B
Reference Time 0x0000005e
Sectors Read 0x0000000011173823
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x00000000000003be
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0x0054
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Violations

Threshold Violation Flags All Zeroes (256 x [0x00])
Offset To Extended Threshold Violation Flags 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
Total Structure Length 0 (0x00000000)
Fixed Structure Length 0 (0x00000000)

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Parameter Control

Serial Number 0x8054
Firmware Revision 0x8248
Product Revision 0x8268
Reference Time 0x8184
Sectors Read 0x8108
Read Errors Hard 0x8184
Read Errors Retry Recovered 0x8184
Read Errors ECC Corrected 0x8188
Sectors Written 0x8108
Write Errors Hard 0x8184
Write Errors Retry Recovered 0x8184
Seek Count 33032 (0x8108)
Seek Errors 0x8188
Spin Cycles 0x8184
Spin Up Time 0x8a82
Performance Test 1 0x0a82
Performance Test 2 0x8a82
Performance Test 3 0x8a82
Performance Test 4 0x8a82
Reallocation Sects 0x0a04
Reallocated Sects 0x8d84
DRQ Timeouts 0x0982
Other Timeouts 0x0182
Drive Rebuild Count 386 (0x0182)
Spin Retries 2434 (0x0982)
Recovers Failed Read 0x8182
Recovers Failed Write 0x0182
Format Errors 0x0182
Self Test Failures 0x0982
Not Ready Failures 0x0184
Remap Abort Failures 0x0984
IRQ Deglitch Count 0x0984
Bus Faults 33156 (0x8184)
Hot Plug Count 0x0184
Track Rewrite Errors 0x0982
Write Errors After Remap 0x0982
Background Firmware Revision 0x0a48
Media Failures 0x0182
Hardware Errors 0x0182
Aborted Command Failures 0x0182
Spin Up Failures 0x0182
Bad Target Count 386 (0x0182)
Predictive Failure Errors 0x2184

800 ₽
800 ₽
BF1468B26B, no warnings, no errors

Комплектация:
HDD HP BF14688286, P/N:360209-005 (ST3146854LC)
Салазки HP Spare 347779-001
Тест поверхности:
Сектор начала тестирования: 0
Сектор конца тестирования: 286 374 239
Протестировано от общего объема в %: 100
Результаты сканирования: no warnings, no errors
Подробнее смотри скриншот результатов проверки Victoria 4.47

--------- ADUReaport.txt ---------
Time Generated: Friday December 09, 2016 5:31:39PM

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Physical Drive Status

SCSI Bus 0 (0x00)
SCSIID 5 (0x05)
Block Size 512 Bytes Per Block (0x0200)
Total Blocks 146.8 GB (0x11175330)
Reserved Blocks 0x00000440
Drive Model COMPAQ BF14688286
Drive Serial Number 3KN05P0600007535G6TF
Drive Firmware Revision HPB3
SCSI Inquiry Bits 0x3e
Compaq Drive Stamped Stamped For Monitoring (0x01)
Last Failure Reason Hot Removed (0x14)
Device Flags 0xcd
Position Device Flag Status
-------- ----------------------------- -------------
0 Drive Present And Operational Informational
2 Wide SCSI Transfers Enabled Informational
3 Synchronous Transfers Enabled Informational
6 Ultra SCSI Transfers Enabled Informational
7 Ultra2 SCSI Transfers Enabled Informational

More Device Flags 0x25
Position Device Flag Status
-------- ------------------------------------- -------------
0 SMART Predictive Failure Supported Informational
2 SMART Predictive Failure Is Enabled Informational
4 Device Attached To Internal Connector Informational
5 Configured Data Drive Informational

SCSI Lun 0x00
Yet More Device Flags 0x9d
Position Device Flag Status
-------- --------------------------------------- -------------
0 DT Clocking Mode Informational
2 DT And ST Clocking Supported Informational
3 U320 Transfers Enabled Informational
4 Supports Packetized SCSI Informational
7 Drive Write Cache Setting Is Changeable Informational

Even More Device Flags 0x05
Position Device Flag Status
-------- ------------------------- -------------
0 QAS Is Supported Informational
2 SCSI Arbitration Fairness Informational

Spi Speed Rules 0xf8b70800
Physical Port J1
Physical Box 0 (0x00)
Physical Bay 5 (0x05)
RPM 15000 RPM (0x00003aa7)
Device Type Parallel (0x00)
SATA Version 0x00
Big Total Block Count 0x0000000000000000
RIS Starting LBA 0x0000000000000000
RIS Size 0 MB (0x00000000)
WWID All Zeroes (20 x [0x00])
Controller PHY Map All Zeroes (32 x [0x00])
PHY Count 0 (0x0000)
PHY Connected Device Type All Zeroes (256 x [0x00])
PHY To Drive Bay Number All Zeroes (256 x [0x00])
PHY To Attached Device Index All Zeroes (256 x [0x0000])
Box Index 0 (0x00)
MSA Support 0x00
Extra Device Flags 0x0000
Negotiated Link Rate All Zeroes (256 x [0x00])
Phy To Phy Map All Zeroes (256 x [0x00])
Redundant Path Present Map 0x00
Redundant Path Failure Map 0x00
Active Path Number 0x00
Multi Path Port 1 empty
Multi Path Port 2 empty
Multi Path Port 3 empty
Multi Path Port 4 empty
Multi Path Port 5 empty
Multi Path Port 6 empty
Multi Path Port 7 empty
Multi Path Port 8 empty
Multi Path Box 1 0x00
Multi Path Box 2 0x00
Multi Path Box 3 0x00
Multi Path Box 4 0x00
Multi Path Box 5 0x00
Multi Path Box 6 0x00
Multi Path Box 7 0x00
Multi Path Box 8 0x00
Multi LUN Device LUN Count 0x00
Minimum Good Firmware Revision empty
Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00])
Current Temperature 0x00
Temperature Threshold 0x00
Maximum Temperature 0x00
Logical Blocks Per Physical Block 0x00
Current Q Depth Limit 0x0000
Switch Name All Zeroes (10 x [0x00])
Switch Port 0x0000
Alternate Paths Switch Name All Zeroes (40 x [0x00])
Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Power On Hours 0x0000
Percent Endurance Used 0x0000
Drive Authentication 0x00
Smart Carrier Authentication 0x00
Smart Carrier Application Version 0x00
Smart Carrier Bootloader Version 0x00

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Factory)

Serial Number 3KN05P0600007535G6TF
Firmware Revision HPB2
Product Revision COMPAQ BF14688286
Reference Time 0x0050f77f
Sectors Read 0x000000aaee2d872f
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x0000001c2805fe4d
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0xffff
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Reset)

Serial Number 3KN05P0600007535G6TF
Firmware Revision HPB3
Product Revision COMPAQ BF14688286
Reference Time 0x0000005e
Sectors Read 0x0000000011173802
Read Errors Hard 0x00000000
Read Errors Retry Recovered 0x00000000
Read Errors ECC Corrected 0x0000000000000000
Sectors Written 0x00000000000001fc
Write Errors Hard 0x00000000
Write Errors Retry Recovered 0x00000000
Seek Count 0x0000000000000000
Seek Errors 0x0000000000000000
Spin Cycles 0x00000001
Spin Up Time 0x018f
Performance Test 1 0xffff
Performance Test 2 0xffff
Performance Test 3 0xffff
Performance Test 4 0xffff
Reallocation Sectors 0xffffffff
Reallocated Sectors 0xffffffff
DRQ Time Outs 0xffff
Other Time Outs 0x0000
Drive Rebuild Count 0 (0x0000)
Spin Retries 65535 (0xffff)
Recovers Failed Read 0x0000
Recovers Failed Write 0x0000
Format Errors 0x0000
Self Test Failures 0xffff
Not Ready Failures 0x00000000
Remap Abort Failures 0xffffffff
IRQ Deglitch Count 4294967295 (0xffffffff)
Bus Faults 0x00000000
Hot Plug Count 0 (0x00000000)
Track Rewrite Errors 0xffff
Write Errors After Remap 0xffff
Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
Media Failures 0x0000
Hardware Errors 0x0000
Aborted Command Failures 0x0000
Spin Up Failures 0x0000
Bad Target Count 0 (0x0000)
Predictive Failure Errors 0x00000000

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Violations

Threshold Violation Flags All Zeroes (256 x [0x00])
Offset To Extended Threshold Violation Flags 0 (0x0000)
Maximum Physical Devices Supported 0 (0x0000)
Total Structure Length 0 (0x00000000)
Fixed Structure Length 0 (0x00000000)

Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Parameter Control

Serial Number 0x8054
Firmware Revision 0x8248
Product Revision 0x8268
Reference Time 0x8184
Sectors Read 0x8108
Read Errors Hard 0x8184
Read Errors Retry Recovered 0x8184
Read Errors ECC Corrected 0x8188
Sectors Written 0x8108
Write Errors Hard 0x8184
Write Errors Retry Recovered 0x8184
Seek Count 33032 (0x8108)
Seek Errors 0x8188
Spin Cycles 0x8184
Spin Up Time 0x8a82
Performance Test 1 0x0a82
Performance Test 2 0x8a82
Performance Test 3 0x8a82
Performance Test 4 0x8a82
Reallocation Sects 0x0a04
Reallocated Sects 0x8d84
DRQ Timeouts 0x0982
Other Timeouts 0x0182
Drive Rebuild Count 386 (0x0182)
Spin Retries 2434 (0x0982)
Recovers Failed Read 0x8182
Recovers Failed Write 0x0182
Format Errors 0x0182
Self Test Failures 0x0982
Not Ready Failures 0x0184
Remap Abort Failures 0x0984
IRQ Deglitch Count 0x0984
Bus Faults 33156 (0x8184)
Hot Plug Count 0x0184
Track Rewrite Errors 0x0982
Write Errors After Remap 0x0982
Background Firmware Revision 0x0a48
Media Failures 0x0182
Hardware Errors 0x0182
Aborted Command Failures 0x0182
Spin Up Failures 0x0182
Bad Target Count 386 (0x0182)
Predictive Failure Errors 0x2184

800 ₽
800 ₽
BF14688286, no warnings, no errors