HP COMPAQ 146Gb 10K
#046-035-002 1 шт на _Шереметьево-1 Филиппины2006
4.0
700 ₽
BD14689BB9, no warnings, no errors
Комплектация: HDD COMPAQ BD14689BB9 Салазки HP Spare 404708-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Monday December 05, 2016 5:02:40PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:4 : Physical Drive Status SCSI Bus 1 (0x01) SCSIID 4 (0x04) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD14689BB9 Drive Serial Number DAA1P630389N0610 Drive Firmware Revision HPB1 SCSI Inquiry Bits 0x3a Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J2 Physical Box 0 (0x00) Physical Bay 4 (0x04) RPM 10000 RPM (0x00002729) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:4 : Monitor and Performance Statistics (Since Factory) Serial Number DAA1P630389N0610 Firmware Revision HPB1 Product Revision COMPAQ BD14689BB9 Reference Time 0x003b908e Sectors Read 0x0000008afacc2796 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000003ef367b42 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000002 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 1 (0x00000001) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:4 : Monitor and Performance Statistics (Since Reset) Serial Number DAA1P630389N0610 Firmware Revision HPB1 Product Revision COMPAQ BD14689BB9 Reference Time 0x000000d0 Sectors Read 0x00000000222e70ff Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000000004ee Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000003 Spin Up Time 0x0085 Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 1 (0x00000001) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:4 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:4 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:4 : Parallel Scsi Physical Drive Error Log Entry Size 20 (0x14) Entry Count 20 (0x0014) Next Entry Offset 0x02 Errors Logged 2 (0x00000002) Physical Drive Error Log Entries Error Type SCSI Operation Code SCSI Status CAM Status Sense Key ASC ASCQ Block Valid Block Reference Time Additional Information ---------- ------------------- ----------- ---------- --------- ---- ---- ----------- ---------- -------------- ---------------------- 0x02 0x28 0x00 0x0e 0x00 0x00 0x00 0x00 0x0e48a530 0x000f580f 0x0000 0x02 0x28 0x00 0x0e 0x00 0x00 0x00 0x00 0x024a9010 0x001041c3 0x0000 Reference Time 0x003b908e Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:4 : Mode Sense 10 Header 0x00 0xd2 0x00 0x10 0x00 0x00 0x00 0x08 0x00 0x00 0x00 0x00 0x00 0x00 0x02 0x00 Mode Page Page Number Page Data ----------- ----------------------------------------------------------------------------------------------------------------------- 0x01 0x81 0x0a 0xe4 0x3f 0xff 0x00 0x00 0x00 0x3f 0x00 0x75 0x30 0x02 0x82 0x0e 0x00 0x00 0x00 0x01 0x00 0x00 0x00 0x00 0x00 0x00 0x70 0x00 0x00 0x00 0x03 0x83 0x16 0x00 0x91 0x00 0xf0 0x00 0x00 0x00 0x5a 0x04 0x8d 0x02 0x00 0x00 0x01 0x01 0x24 0x00 0x71 0x40 0x00 0x00 0x00 0x04 0x84 0x16 0x01 0x33 0xa1 0x05 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x27 0x29 0x00 0x00 0x07 0x87 0x0a 0x04 0x3f 0xff 0x00 0x00 0x00 0x00 0x00 0x75 0x30 0x08 0x88 0x12 0x10 0x00 0xff 0xff 0x00 0x00 0x00 0x00 0xff 0xff 0x80 0x08 0x00 0x00 0x00 0x00 0x00 0x00 0x09 0x89 0x0e 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x04 0x00 0x0a 0x8a 0x0a 0x00 0x10 0x00 0x00 0x00 0x00 0x00 0x00 0x0e 0x38 0x0c 0x0c 0x16 0x80 0x00 0x00 0x12 0x00 0x00 0x00 0x00 0x00 0x00 0x01 0x33 0xa0 0x04 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x08 0x19 0x99 0x06 0x01 0x00 0x00 0x00 0x00 0x00 0x1a 0x9a 0x0a 0x00 0x00 0xff 0xff 0xff 0xff 0xff 0xff 0xff 0xff 0x1c 0x9c 0x0a 0x11 0x04 0x00 0x00 0x0b 0xb8 0x00 0x00 0x00 0x02 0x21 0xa1 0x02 0x0f 0x00
HP COMPAQ 146Gb 10K
#046-035-005 1 шт на _Шереметьево-1 Сингапур2005
4.0
700 ₽
BD1468A4B5, no warnings, no errors
Комплектация: HDD HP BD1468A4B5 Салазки HP Spare 289044-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 374 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Thursday December 08, 2016 12:07:50PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 2 (0x02) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD1468A4B5 Drive Serial Number J403CRLK Drive Firmware Revision HPB8 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason No Failure (0x00) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 2 (0x02) RPM 10000 RPM (0x00002712) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Factory) Serial Number J403CRLK Firmware Revision HPB8 Product Revision COMPAQ BD1468A4B5 Reference Time 0x00345c30 Sectors Read 0x000001436952475f Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000005 Read Errors ECC Corrected 0x00000000000000a8 Sectors Written 0x00000006f0c1d139 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000005 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0022 Drive Rebuild Count 1 (0x0001) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0002 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x0000000b Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000002 Hot Plug Count 1 (0x00000001) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Reset) Serial Number J403CRLK Firmware Revision HPB8 Product Revision COMPAQ BD1468A4B5 Reference Time 0x0000005c Sectors Read 0x0000000011a47333 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000000007d8 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0x009d Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 10K
#046-035-006 1 шт на _Шереметьево-1 Сингапур2006
4.0
700 ₽
BD14688278, no warnings, no errors
Комплектация: HDD HP BD14688278, P/N: 360205-013 Салазки HP Spare 289044-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Thursday December 08, 2016 6:44:20PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 4 (0x04) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD14688278 Drive Serial Number 3KS2FL2700007614G7EC Drive Firmware Revision HPB2 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x95 Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 4 (0x04) RPM 10000 RPM (0x00002731) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Factory) Serial Number 3KS2FL2700007614G7EC Firmware Revision HPB2 Product Revision COMPAQ BD14688278 Reference Time 0x002fb3bc Sectors Read 0x00000071fa95f881 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000003f751582c Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Reset) Serial Number 3KS2FL2700007614G7EC Firmware Revision HPB2 Product Revision COMPAQ BD14688278 Reference Time 0x000000ad Sectors Read 0x0000000012c08806 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x000000000000019c Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000000 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 10K
#046-035-007 1 шт на _Шереметьево-1 Филипины2005
4.0
700 ₽
BD1468856B, warning - 265, errors - 0
Комплектация: HDD HP BD1468856B, Part# : 365695-002 (CT: 2856B01CXRX25M) Салазки HP Spare 289044-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Friday December 09, 2016 2:25:24PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 3 (0x03) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD1468856B Drive Serial Number AAA1P5707NDM0527 Drive Firmware Revision HPB2 SCSI Inquiry Bits 0x3a Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Timeout (0x07) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 3 (0x03) RPM 10000 RPM (0x00002729) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Factory) Serial Number AAA1P5707NDM0527 Firmware Revision HPB2 Product Revision COMPAQ BD1468856B Reference Time 0x003d101e Sectors Read 0x0000000f95f4c88e Read Errors Hard 0x00000001 Read Errors Retry Recovered 0x0000014a Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000d503442c0 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000002 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xfffffffe DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Reset) Serial Number AAA1P5707NDM0527 Firmware Revision HPB2 Product Revision COMPAQ BD1468856B Reference Time 0x000000e5 Sectors Read 0x00000000111739e3 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000074 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000000006a7 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000000 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xfffffffe DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 10K
#046-035-008 1 шт на _Шереметьево-1 Сингапур2006
4.0
700 ₽
BD14688278, no warnings, no errors
Комплектация: HDD HP BD14688278,P/N: 360205-013 (ST3146707LC) Салазки HP Spare 289044-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Friday December 09, 2016 2:25:24PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 5 (0x05) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD14688278 Drive Serial Number 3KS2C5K1000076169XC4 Drive Firmware Revision HPB4 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 5 (0x05) RPM 10000 RPM (0x00002731) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Factory) Serial Number 3KS2C5K1000076169XC4 Firmware Revision HPB4 Product Revision COMPAQ BD14688278 Reference Time 0x003897ce Sectors Read 0x0000000ec1f689e3 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000cb5002f34 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000002 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Reset) Serial Number 3KS2C5K1000076169XC4 Firmware Revision HPB4 Product Revision COMPAQ BD14688278 Reference Time 0x000000e5 Sectors Read 0x0000000011173f9f Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000000002b2 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000000 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 10K
#046-035-009 1 шт на _Шереметьево-1 Сингапур2006
4.0
700 ₽
BD14688278, no warnings, no errors
Комплектация: HDD HP BD14688278, P/N: 360205-013 (ST3146707LC) Салазки HP Spare 289044-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Friday December 09, 2016 2:25:24PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 2 (0x02) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD14688278 Drive Serial Number 3KS2FEHK00007614VD0B Drive Firmware Revision HPB2 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 2 (0x02) RPM 10000 RPM (0x00002731) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Factory) Serial Number 3KS2FEHK00007614VD0B Firmware Revision HPB2 Product Revision COMPAQ BD14688278 Reference Time 0x002fb455 Sectors Read 0x000000721d923b9e Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x000000040fb03996 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Reset) Serial Number 3KS2FEHK00007614VD0B Firmware Revision HPB2 Product Revision COMPAQ BD14688278 Reference Time 0x000000e5 Sectors Read 0x000000001117398c Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000000009d4 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000000 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 10K
#046-035-010 1 шт на _Шереметьево-1 Филипины2007
4.0
700 ₽
BD14689BB9, no warnings, no errors
Комплектация: HDD HP BD14689BB9, Part# : 365695-008 (CT: 29BB901CXVG22Y) Салазки HP Spare 404708-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Friday December 09, 2016 3:48:25PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 3 (0x03) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD14689BB9 Drive Serial Number DEA1P7C06DW30750 Drive Firmware Revision HPB1 SCSI Inquiry Bits 0x3a Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 3 (0x03) RPM 10000 RPM (0x00002729) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Factory) Serial Number DEA1P7C06DW30750 Firmware Revision HPB1 Product Revision COMPAQ BD14689BB9 Reference Time 0x003663c0 Sectors Read 0x0000005ba57233e8 Read Errors Hard 0x00000005 Read Errors Retry Recovered 0x0000004d Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000dec11a569 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Reset) Serial Number DEA1P7C06DW30750 Firmware Revision HPB1 Product Revision COMPAQ BD14689BB9 Reference Time 0x00000049 Sectors Read 0x00000000111738bc Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x000000000000059d Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0x0085 Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 10K
#046-035-011 1 шт на _Шереметьево-1 Сингапур2005
4.0
700 ₽
BD1468A4B5, warnings - 12, errors -1
Комплектация: HDD HP BD1468A4B5, P/N: 356910-008 Салазки HP Spare 284490-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 374 239 Протестировано от общего объема в %: 100 Результаты сканирования: warnings - 12, errors -1 Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Tuesday December 13, 2016 11:57:17AM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 4 (0x04) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD1468A4B5 Drive Serial Number J403DCBK Drive Firmware Revision HPB8 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 4 (0x04) RPM 10000 RPM (0x00002712) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Factory) Serial Number J403DCBK Firmware Revision HPB8 Product Revision COMPAQ BD1468A4B5 Reference Time 0x003feb01 Sectors Read 0x0000022e077c7fac Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000008a8aec762 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Reset) Serial Number J403DCBK Firmware Revision HPB8 Product Revision COMPAQ BD1468A4B5 Reference Time 0x00000070 Sectors Read 0x00000000111770ee Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000000162ea Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0x009d Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 10K
#046-035-012 1 шт на _Шереметьево-1 Филипины2006
4.0
700 ₽
BD14689BB9, no warnings, no errors
Комплектация: HDD HP BD14689BB9, P/N: 365695-008 Салазки HP Spare 289044-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Tuesday December 13, 2016 11:57:17AM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 2 (0x02) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD14689BB9 Drive Serial Number DAA1P63032KV0609 Drive Firmware Revision HPB1 SCSI Inquiry Bits 0x3a Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 2 (0x02) RPM 10000 RPM (0x00002729) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Factory) Serial Number DAA1P63032KV0609 Firmware Revision HPB1 Product Revision COMPAQ BD14689BB9 Reference Time 0x0030c1a3 Sectors Read 0x00000007bcc08d7c Read Errors Hard 0x0000006b Read Errors Retry Recovered 0x00000008 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x000000077553d116 Write Errors Hard 0x00000006 Write Errors Retry Recovered 0x0000000e Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xfffffffe DRQ Time Outs 0xffff Other Time Outs 0x0004 Drive Rebuild Count 1 (0x0001) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Reset) Serial Number DAA1P63032KV0609 Firmware Revision HPB1 Product Revision COMPAQ BD14689BB9 Reference Time 0x00000071 Sectors Read 0x0000000011176ce1 Read Errors Hard 0x0000006b Read Errors Retry Recovered 0x00000002 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000000008ad Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xfffffffe DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 10K
#046-035-013 1 шт на _Шереметьево-1 Сингапур2007
4.0
700 ₽
BD14688278, no warnings, no errors
Комплектация: HDD HP BD14688278, P/N: 360205-013 (ST314670LC) Салазки HP Spare 289044-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Tuesday December 13, 2016 1:57:11PM Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 2 (0x02) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD14688278 Drive Serial Number 3KS1QWNX00007602U4X0 Drive Firmware Revision HPB2 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Plug Start Unit Failed (0x1c) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x07 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 1 QAS Is Enabled Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0x78b90800 Physical Port J3 Physical Box 0 (0x00) Physical Bay 2 (0x02) RPM 10000 RPM (0x00002731) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Factory) Serial Number 3KS1QWNX00007602U4X0 Firmware Revision HPB2 Product Revision COMPAQ BD14688278 Reference Time 0x0033bba1 Sectors Read 0x0000002b6c1d93b7 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x000000021875cdf8 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000002 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 1 (0x0001) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Reset) Serial Number 3KS1QWNX00007602U4X0 Firmware Revision HPB2 Product Revision COMPAQ BD14688278 Reference Time 0x000000de Sectors Read 0x0000000011173806 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000000005fc Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0x00ae Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 10K
#046-035-014 1 шт на _Шереметьево-1 Сингапур2005
4.0
700 ₽
BD1468A4B5, no warnings, no errors
Комплектация: HDD HP BD1468A4B5, P/N: 356910-008 Салазки HP Spare 289044-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Tuesday December 13, 2016 4:55:26PM Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:1 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 1 (0x01) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD1468A4B5 Drive Serial Number J403DMRK Drive Firmware Revision HPB8 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason No Failure (0x00) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x07 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 1 QAS Is Enabled Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0x78b90800 Physical Port J3 Physical Box 0 (0x00) Physical Bay 1 (0x01) RPM 10000 RPM (0x00002712) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:1 : Monitor and Performance Statistics (Since Factory) Serial Number J403DMRK Firmware Revision HPB8 Product Revision COMPAQ BD1468A4B5 Reference Time 0x003feaff Sectors Read 0x0000022db2aa4a0f Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000007 Sectors Written 0x00000008a8ebf68d Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000000 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:1 : Monitor and Performance Statistics (Since Reset) Serial Number J403DMRK Firmware Revision HPB8 Product Revision COMPAQ BD1468A4B5 Reference Time 0x0000006e Sectors Read 0x0000000011176e6e Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x000000000001670e Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000000 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:1 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:1 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 10K
#046-035-015 1 шт на _Шереметьево-1 Сингапур2005
4.0
700 ₽
BD14687B52, no warnings, no errors
Комплектация: HDD HP BD14687B52, P/N: 356910-002 Салазки HP Spare 289044-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Tuesday December 13, 2016 4:55:26PM Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:0 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 0 (0x00) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD14687B52 Drive Serial Number D40RAMZK Drive Firmware Revision HPB7 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason No Failure (0x00) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x07 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 1 QAS Is Enabled Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0x78b90800 Physical Port J3 Physical Box 0 (0x00) Physical Bay 0 (0x00) RPM 10000 RPM (0x00002712) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:0 : Monitor and Performance Statistics (Since Factory) Serial Number D40RAMZK Firmware Revision HPB7 Product Revision COMPAQ BD14687B52 Reference Time 0x0032c329 Sectors Read 0x000000af0f946be2 Read Errors Hard 0x0000000a Read Errors Retry Recovered 0x00000001 Read Errors ECC Corrected 0x0000000000000001 Sectors Written 0x0000000406301a45 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000006 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0029 Drive Rebuild Count 2 (0x0002) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0002 Recovers Failed Write 0x0001 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000009 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000006 Hot Plug Count 2 (0x00000002) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:0 : Monitor and Performance Statistics (Since Reset) Serial Number D40RAMZK Firmware Revision HPB7 Product Revision COMPAQ BD14687B52 Reference Time 0x0000006e Sectors Read 0x0000000011173885 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000000000ac6 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000000 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:0 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:0 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 10K
#046-035-016 1 шт на _Шереметьево-1 Сингапур2007
4.0
700 ₽
BD14688278, no warnings, no errors
Комплектация: HDD HP BD14688278, P/N: 360205-013 Салазки HP Spare 289044-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Tuesday December 13, 2016 4:55:26PM Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 3 (0x03) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD14688278 Drive Serial Number 3KS0PJC400007538H6A6 Drive Firmware Revision HPB1 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason No Failure (0x00) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x07 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 1 QAS Is Enabled Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0x78b90800 Physical Port J3 Physical Box 0 (0x00) Physical Bay 3 (0x03) RPM 10000 RPM (0x00002731) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Factory) Serial Number 3KS0PJC400007538H6A6 Firmware Revision HPB1 Product Revision COMPAQ BD14688278 Reference Time 0x00345e83 Sectors Read 0x000001435ede21ae Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000706243d27 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000002 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0001 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000001 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Reset) Serial Number 3KS0PJC400007538H6A6 Firmware Revision HPB1 Product Revision COMPAQ BD14688278 Reference Time 0x0000006e Sectors Read 0x0000000011173ac6 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000000004d0 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000000 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 10K
#046-035-017 1 шт на _Шереметьево-1 Сингапур2007
4.0
700 ₽
BD14688278, no warnings, no errors
Комплектация: HDD HP BD14688278, P/N: 360205-013 Салазки HP Spare 289044-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Tuesday December 13, 2016 4:55:26PM Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 2 (0x02) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD14688278 Drive Serial Number 3KS2M2ZH000076161WTD Drive Firmware Revision HPB4 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason No Failure (0x00) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x07 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 1 QAS Is Enabled Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0x78b90800 Physical Port J3 Physical Box 0 (0x00) Physical Bay 2 (0x02) RPM 10000 RPM (0x00002731) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Factory) Serial Number 3KS2M2ZH000076161WTD Firmware Revision HPB4 Product Revision COMPAQ BD14688278 Reference Time 0x00345e24 Sectors Read 0x000000cdb2ad41c8 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x000000046e80ec0c Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000003 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0008 Drive Rebuild Count 1 (0x0001) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000009 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Reset) Serial Number 3KS2M2ZH000076161WTD Firmware Revision HPB4 Product Revision COMPAQ BD14688278 Reference Time 0x0000006e Sectors Read 0x0000000011173d99 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000000000692 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000000 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 10K
#046-035-018 1 шт на _Шереметьево-1 Филипины2007
4.0
700 ₽
BD14689BB9, no warnings, no errors
Комплектация: HDD HP BD14689BB9, P/N: 365695-008 Салазки HP Spare 289044-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Tuesday December 13, 2016 4:55:26PM Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 5 (0x05) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD14689BB9 Drive Serial Number DAA1P5B00G760547 Drive Firmware Revision HPB1 SCSI Inquiry Bits 0x3a Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason No Failure (0x00) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x05 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x07 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 1 QAS Is Enabled Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0x78b90800 Physical Port J3 Physical Box 0 (0x00) Physical Bay 5 (0x05) RPM 10000 RPM (0x00002729) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Factory) Serial Number DAA1P5B00G760547 Firmware Revision HPB1 Product Revision COMPAQ BD14689BB9 Reference Time 0x00345e87 Sectors Read 0x00000149af0cf39e Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000006fe38d34c Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x000b Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000009 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Reset) Serial Number DAA1P5B00G760547 Firmware Revision HPB1 Product Revision COMPAQ BD14689BB9 Reference Time 0x0000006e Sectors Read 0x000000000000009c Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000000000b6 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000000 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 10K
#046-035-019 1 шт на _Шереметьево-1 Сингапур2007
4.0
700 ₽
BD14688278, no warnings, no errors
Комплектация: HDD HP BD14688278, P/N: 360205-053 (ST3146707LC) Салазки HP Spare 289044-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Tuesday December 13, 2016 4:56:57PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 2 (0x02) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD14688278 Drive Serial Number 3KS0MTB500007539FS4G Drive Firmware Revision HPB1 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 2 (0x02) RPM 10000 RPM (0x00002731) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Factory) Serial Number 3KS0MTB500007539FS4G Firmware Revision HPB1 Product Revision COMPAQ BD14688278 Reference Time 0x00345f5c Sectors Read 0x0000011d77527ece Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x000000129c930905 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000000 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Reset) Serial Number 3KS0MTB500007539FS4G Firmware Revision HPB1 Product Revision COMPAQ BD14688278 Reference Time 0x00000070 Sectors Read 0x0000000011173c76 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000000008fa Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 10K
#046-035-020 1 шт на _Шереметьево-1 Филипины2005
4.0
700 ₽
BD14689BB9, no warnings, no errors
Комплектация: HDD BD14689BB9, P/N: 365695-008 Салазки HP Spare 289044-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Tuesday December 13, 2016 4:56:57PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 3 (0x03) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD14689BB9 Drive Serial Number DAA1P5B00HCV0547 Drive Firmware Revision HPB1 SCSI Inquiry Bits 0x3a Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 3 (0x03) RPM 10000 RPM (0x00002729) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Factory) Serial Number DAA1P5B00HCV0547 Firmware Revision HPB1 Product Revision COMPAQ BD14689BB9 Reference Time 0x00345e89 Sectors Read 0x0000014c5d20b4ad Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000005 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000006fe349f46 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000002 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0008 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000009 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Reset) Serial Number DAA1P5B00HCV0547 Firmware Revision HPB1 Product Revision COMPAQ BD14689BB9 Reference Time 0x00000070 Sectors Read 0x0000000011173b45 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000000006a2 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 10K
#046-035-021 1 шт на _Шереметьево-1 Филипины2005
4.0
700 ₽
BD14689BB9, no warnings, no errors
Комплектация: HDD HP BD14689BB9, P/N: 365695-008 Салазки HP Spare 289044-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Tuesday December 13, 2016 4:56:57PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 4 (0x04) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD14689BB9 Drive Serial Number DAA1P5B00HE70547 Drive Firmware Revision HPB1 SCSI Inquiry Bits 0x3a Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 4 (0x04) RPM 10000 RPM (0x00002729) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Factory) Serial Number DAA1P5B00HE70547 Firmware Revision HPB1 Product Revision COMPAQ BD14689BB9 Reference Time 0x00345dd5 Sectors Read 0x0000013edca23610 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000bd93baf5c Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000000 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0009 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0004 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Reset) Serial Number DAA1P5B00HE70547 Firmware Revision HPB1 Product Revision COMPAQ BD14689BB9 Reference Time 0x00000070 Sectors Read 0x0000000011173a26 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x000000000000043a Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 10K
#046-035-022 1 шт на _Шереметьево-1 Сингапур2007
4.0
700 ₽
BD1468A4C5, no warnings, no errors
Комплектация: HDD HP BD1468A4C5, P/N: 360205-022 (ST 3146707LC) Салазки HP Spare 289044-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Tuesday December 13, 2016 4:56:57PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 5 (0x05) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD1468A4C5 Drive Serial Number 3KS2YL3C00007621EYTC Drive Firmware Revision HPB4 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 5 (0x05) RPM 10000 RPM (0x00002731) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Factory) Serial Number 3KS2YL3C00007621EYTC Firmware Revision HPB4 Product Revision COMPAQ BD1468A4C5 Reference Time 0x00345f5c Sectors Read 0x00000140d68e7197 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x000000129c5a7005 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x0000000f Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0001 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000001 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Reset) Serial Number 3KS2YL3C00007621EYTC Firmware Revision HPB4 Product Revision COMPAQ BD1468A4C5 Reference Time 0x00000070 Sectors Read 0x00000000111738e9 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000000000278 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 10K
#046-035-023 1 шт на _Шереметьево-1 Филипины2005
4.0
700 ₽
BD1468856B, no warnings, no errors
Комплектация: HDD HP BD1468856B, P/N: 365695-002 Салазки HP Spare 289044-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Friday December 23, 2016 4:09:06PM Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:0 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 0 (0x00) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BD1468856B Drive Serial Number AAA1P5406B6K0515 Drive Firmware Revision HPB2 SCSI Inquiry Bits 0x3a Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x07 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 1 QAS Is Enabled Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0x78b90800 Physical Port J3 Physical Box 0 (0x00) Physical Bay 0 (0x00) RPM 10000 RPM (0x00002729) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:0 : Monitor and Performance Statistics (Since Factory) Serial Number AAA1P5406B6K0515 Firmware Revision HPB2 Product Revision COMPAQ BD1468856B Reference Time 0x001c2006 Sectors Read 0x0000002945204637 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x0000000b Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000c74d743b Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xfffffffe DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000001 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:0 : Monitor and Performance Statistics (Since Reset) Serial Number AAA1P5406B6K0515 Firmware Revision HPB2 Product Revision COMPAQ BD1468856B Reference Time 0x0000019e Sectors Read 0x00000000111772d6 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000002 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000000004f3 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xfffffffe DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:0 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6400 in slot 3 : Internal Drive Cage at Box 1 : Drive Cage on Port J3 : Physical Drive (146.8 GB Parallel SCSI) 1:0 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 15K
#046-034-001 1 шт на _Шереметьево-1 Сингапур2005
4.0
800 ₽
BF1468A4B3, no warnings, no errors
Комплектация: HDD COMPAQ BF1468A4B3 Салазки HP Spare 404712-001 Тест поверхности: Victoria 4.47 Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 BAD-сектора: 0 см. скриншот результатов проверки --------- ADUReaport.txt --------- ********* Блок заголовка файла ********* ACU Version 9.40.12.0 Diagnostic Module Version 6.2.25.0 INFOMGR Version 6.1.29.0 Time Generated Monday December 05, 2016 11:23:14AM ********* Блок о HDD ********* Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:2 : Physical Drive Status SCSI Bus 1 (0x01) SCSIID 2 (0x02) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BF1468A4B3 Drive Serial Number JAW5RH5K Drive Firmware Revision HPB8 SCSI Inquiry Bits 0x3a Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Timeout (0x07) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J2 Physical Box 0 (0x00) Physical Bay 2 (0x02) RPM 15000 RPM (0x00003a98) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Sanititze Erase Support 0x00 Encryption Flags 0x00 Encryption Key Name empty Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:2 : Monitor and Performance Statistics (Since Factory) Serial Number JAW5RH5K Firmware Revision HPB5 Product Revision COMPAQ BF1468A4B3 Reference Time 0x00300b3f Sectors Read 0x0000004ab53c3a10 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000255a545fe Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000002 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 1 (0x0001) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 1 (0x00000001) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:2 : Monitor and Performance Statistics (Since Reset) Serial Number JAW5RH5K Firmware Revision HPB8 Product Revision COMPAQ BF1468A4B3 Reference Time 0x00000056 Sectors Read 0x0000000011173d23 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000000000851 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:2 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:2 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:2 : Parallel Scsi Physical Drive Error Log Entry Size 20 (0x14) Entry Count 20 (0x0014) Next Entry Offset 0x01 Errors Logged 1 (0x00000001) Physical Drive Error Log Entries Error Type SCSI Operation Code SCSI Status CAM Status Sense Key ASC ASCQ Block Valid Block Reference Time Additional Information ---------- ------------------- ----------- ---------- --------- ---- ---- ----------- ---------- -------------- ---------------------- 0x01 0x00 0x02 0x04 0x06 0x29 0x03 0x00 0x00000000 0x00151a6d 0x0000 Reference Time 0x00300b3f Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (146.8 GB Parallel SCSI) 2:2 : Mode Sense 10 Header 0x00 0xde 0x00 0x10 0x00 0x00 0x00 0x08 0x00 0x00 0x00 0x00 0x00 0x00 0x02 0x00 Mode Page Page Number Page Data ----------- ----------------------------------------------------------------------------------------------------------------------- 0x00 0x80 0x0e 0x00 0xa1 0x00 0x12 0x00 0x00 0x40 0x4b 0x00 0x3c 0x10 0x20 0x00 0x20 0x01 0x81 0x0a 0xe4 0x01 0x00 0x00 0x00 0x00 0x01 0x00 0x00 0x00 0x02 0x82 0x0e 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x70 0x00 0x00 0x00 0x03 0x03 0x16 0x13 0x5f 0x00 0x00 0x00 0x00 0x00 0x00 0x03 0x48 0x02 0x00 0x00 0x01 0x00 0x00 0x00 0x28 0x40 0x00 0x00 0x00 0x04 0x04 0x16 0x00 0xa4 0x07 0x0a 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x3a 0x98 0x00 0x00 0x07 0x87 0x0a 0x04 0x01 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x08 0x88 0x12 0x00 0x00 0xff 0xff 0x00 0x00 0xff 0xff 0xff 0xff 0x00 0x0e 0x00 0x00 0x00 0x00 0x00 0x00 0x09 0x89 0x0e 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x04 0x00 0x0a 0x8a 0x0a 0x00 0x10 0x00 0x00 0x00 0x00 0x00 0x00 0x09 0x6b 0x0c 0x8c 0x16 0x80 0x00 0x00 0x18 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0xa4 0x5a 0x09 0x00 0x00 0x00 0x00 0x00 0x00 0x10 0x0c 0x19 0x99 0x06 0x01 0x00 0x00 0x00 0x00 0x00 0x1a 0x9a 0x0a 0x00 0x00 0xff 0xff 0xff 0xff 0xff 0xff 0xff 0xff 0x1c 0x9c 0x0a 0x11 0x04 0x00 0x00 0x0b 0xb8 0x00 0x00 0x00 0x02
HP COMPAQ 146Gb 15K
#046-034-002 1 шт на _Шереметьево-1 Сингапур2005
4.0
800 ₽
BF1468A4CC, no warnings, no errors
Комплектация: HDD HP BF1468A4CC Салазки HP Spare 404712-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Thursday December 08, 2016 12:07:50PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 5 (0x05) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BF1468A4CC Drive Serial Number 3KN28RD000009709PX47 Drive Firmware Revision HPB5 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason No Failure (0x00) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 5 (0x05) RPM 15000 RPM (0x00003aa7) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Factory) Serial Number 3KN28RD000009709PX47 Firmware Revision HPB5 Product Revision COMPAQ BF1468A4CC Reference Time 0x0033eedf Sectors Read 0x00000039d9994309 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x000000000000000a Sectors Written 0x000000115eaf752d Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Reset) Serial Number 3KN28RD000009709PX47 Firmware Revision HPB5 Product Revision COMPAQ BF1468A4CC Reference Time 0x0000005c Sectors Read 0x0000000012028032 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000000001fc Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0x0099 Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 15K
#046-034-003 1 шт на _Шереметьево-1 Сингапур2006
4.0
800 ₽
BF1468A4CC, no warnings, no errors
Комплектация: HDD HP BF1468A4CC Салазки HP Spare 404712-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Thursday December 08, 2016 12:07:50PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 5 (0x05) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BF1468A4CC Drive Serial Number 3KN28RD000009709PX47 Drive Firmware Revision HPB5 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason No Failure (0x00) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 5 (0x05) RPM 15000 RPM (0x00003aa7) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Factory) Serial Number 3KN28RD000009709PX47 Firmware Revision HPB5 Product Revision COMPAQ BF1468A4CC Reference Time 0x0033eedf Sectors Read 0x00000039d9994309 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x000000000000000a Sectors Written 0x000000115eaf752d Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Reset) Serial Number 3KN28RD000009709PX47 Firmware Revision HPB5 Product Revision COMPAQ BF1468A4CC Reference Time 0x0000005c Sectors Read 0x0000000012028032 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000000001fc Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0x0099 Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Parallel Scsi Physical Drive Error Log Entry Size 20 (0x14) Entry Count 20 (0x0014) Next Entry Offset 0x0b Errors Logged 11 (0x0000000b) Physical Drive Error Log Entries Error Type SCSI Operation Code SCSI Status CAM Status Sense Key ASC ASCQ Block Valid Block Reference Time Additional Information ---------- ------------------- ----------- ---------- --------- ---- ---- ----------- ---------- -------------- ---------------------- 0x02 0x28 0x00 0x0e 0x00 0x00 0x00 0x00 0x01b96bc0 0x0007a984 0x0000 0x01 0x28 0x02 0x04 0x01 0x18 0x02 0x01 0x05296fc3 0x00155912 0x0000 0x01 0x28 0x02 0x04 0x01 0x18 0x02 0x01 0x0574aa24 0x0027e30b 0x0000 0x01 0x28 0x02 0x04 0x01 0x18 0x02 0x01 0x0574aa20 0x00291c26 0x0000 0x01 0x28 0x02 0x04 0x01 0x18 0x02 0x01 0x05058c3c 0x0029b2c8 0x0000 0x01 0x28 0x02 0x04 0x01 0x18 0x02 0x01 0x05058c42 0x0029b2c8 0x0000 0x01 0x28 0x02 0x04 0x01 0x18 0x02 0x01 0x0574aa27 0x0029c544 0x0000 0x01 0x28 0x02 0x04 0x01 0x18 0x07 0x01 0x05058c28 0x0029c992 0x0000 0x01 0x28 0x02 0x04 0x01 0x18 0x02 0x01 0x0574b3b3 0x002a4a5c 0x0000 0x01 0x28 0x02 0x04 0x01 0x18 0x02 0x01 0x0528e732 0x002b01d0 0x0000 0x01 0x28 0x02 0x04 0x01 0x18 0x02 0x01 0x0574b3b0 0x002cf5c5 0x0000 Reference Time 0x0033eedf Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Mode Sense 10 Header 0x00 0xd6 0x00 0x10 0x00 0x00 0x00 0x08 0x00 0x00 0x00 0x00 0x00 0x00 0x02 0x00 Mode Page Page Number Page Data ----------- ----------------------------------------------------------------------------------------------------------------------- 0x00 0x80 0x06 0x00 0x00 0x0f 0x00 0x00 0x00 0x01 0x81 0x0a 0xe4 0x0b 0xff 0x00 0x00 0x00 0x05 0x00 0xff 0xff 0x02 0x82 0x0e 0x80 0x80 0x00 0x0a 0x00 0x00 0x00 0x00 0x00 0x00 0x10 0x00 0x00 0x00 0x03 0x83 0x16 0x56 0x20 0x00 0x00 0x00 0x30 0x00 0x00 0x02 0xc2 0x02 0x00 0x00 0x01 0x00 0xdc 0x00 0xaa 0x40 0x00 0x00 0x00 0x04 0x84 0x16 0x00 0xc6 0x88 0x08 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x3a 0xa7 0x00 0x00 0x07 0x87 0x0a 0x04 0x0b 0xff 0x00 0x00 0x00 0x00 0x00 0xff 0xff 0x08 0x88 0x12 0x10 0x00 0xff 0xff 0x00 0x00 0xff 0xff 0xff 0xff 0x00 0x20 0x00 0x00 0x00 0x00 0x00 0x00 0x09 0x89 0x0e 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x04 0x00 0x0a 0x8a 0x0a 0x00 0x10 0x00 0x00 0x00 0x00 0x00 0x00 0x08 0x36 0x0c 0x8c 0x16 0x80 0x00 0x00 0x0f 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0xc6 0x87 0x07 0x00 0x00 0x00 0x00 0x00 0x00 0x10 0x08 0x19 0x19 0x06 0x01 0x00 0xff 0xff 0x00 0x00 0x1a 0x9a 0x0a 0x00 0x00 0xff 0xff 0xff 0xff 0xff 0xff 0xff 0xff 0x1c 0x9c 0x0a 0x11 0x04 0x00 0x00 0x0b 0xb8 0x00 0x00 0x00 0x02 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : VPD Page 80 - Serial Number Product Serial Number 3KN28RD000009709PX47 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : VPD Page 83 - Array Information Array Code Set Identifier Type Association Identifier Length Identifier -------- --------------- ----------- ----------------- --------------------------------------------------------------------------------------------------------------------------------------------------------------- 0x02 0x01 0x00 0x20 0x53 0x45 0x41 0x47 0x41 0x54 0x45 0x20 0x53 0x54 0x33 0x31 0x34 0x36 0x38 0x35 0x34 0x4c 0x43 0x20 0x20 0x20 0x20 0x20 0x33 0x4b 0x4e 0x32 0x38 0x52 0x44 0x30 0x01 0x03 0x00 0x08 0x50 0x01 0x86 0x20 0x00 0x87 0xa4 0x90 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Sense Bus Parameters Peripheral Type 0x03 RMB 0x00 Versions 0x02 Misc 0x02 Additional Length 0x23 Support Bits 0x00 Vendor ID COMPAQ Product ID PROLIANT 6L2I Product Revision 0.10 Inquiry Valid 0x01 Installed Drive Map 0x00000180 Hot Plug Count All Zeroes (32 x [0x0000]) Physical Box 0 (0x00) Alarm Status 0x00 Temp Status 0x00 Valid Alarm Bits 0x00 Alarm Count 0 (0x0000) Specific Alarm Counts All Zeroes (8 x [0x0000]) Connection Flags 0x010a Position Connection Flag Status -------- -------------------------- ------------- 1 Internal Connector Is Used Informational 3 Proliant Storage Detected Informational SCSI Device Revision 0x01 Fan Status 0x00 More Inquiry Data 0x03 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 SCSI Device Type 0x00460e11 Bus Map 0x00003f80 Interrupt Count 0 (0x00000000) Ultra Bus Faults 0x00000000 SCSI Initiator ID 7 (0x07) SCSI Target ID 7 (0x07) Physical Port J2 Big Installed Drive Map 0x00 0x00 0x03 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Big Bus Map 0x00 0x00 0xff 0xff 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Big Box Map 0x00 0x00 0x3f 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Installed Box Map 0x01 More Connection Flags 0x01 Position Connection Flag Status -------- ------------------- ------------- 0 Running In Lvd Mode Informational 2 Using Id Numbering Informational Bay Count 0 (0x00) Expander Count 0 (0x00) Chassis Serial Number empty Fast Bus Faults 0x00000000 Ultra 2 Bus Faults 0x00000000 Ultra 3 Bus Faults 0x00000000 Ultra 320 Bus Faults 0x00000002 SEP Count 0 (0x00) SEP Device Types All Zeroes (16 x [0x00]) SEP Device Numbers All Zeroes (16 x [0x0000]) Expander Device Numbers All Zeroes (16 x [0x0000]) Offset To Extended Installed Drive Map 0 (0x0000) Offset To Extended Bus Map 0 (0x0000) Offset To Extended Box Map 0 (0x0000) Total Structure Length 0 (0x00000000) Offset To Element Type Modules 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) IO Module Present Map 0x00 Active IO Module Number 0x00 IO Module Failure Map 0x00 Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Zoned In Enclosure Bay Map All Zeroes (32 x [0x00]) Position Zoned In Enclosure Bay Status -------- ---------------------- ------------- 0 False Informational 1 False Informational 2 False Informational 3 False Informational 4 False Informational 5 False Informational 6 False Informational 7 False Informational 8 False Informational 9 False Informational 10 False Informational 11 False Informational 12 False Informational 13 False Informational 14 False Informational 15 False Informational 16 False Informational 17 False Informational 18 False Informational 19 False Informational 20 False Informational 21 False Informational 22 False Informational 23 False Informational 24 False Informational 25 False Informational 26 False Informational 27 False Informational 28 False Informational 29 False Informational 30 False Informational 31 False Informational 32 False Informational 33 False Informational 34 False Informational 35 False Informational 36 False Informational 37 False Informational 38 False Informational 39 False Informational 40 False Informational 41 False Informational 42 False Informational 43 False Informational 44 False Informational 45 False Informational 46 False Informational 47 False Informational 48 False Informational 49 False Informational 50 False Informational 51 False Informational 52 False Informational 53 False Informational 54 False Informational 55 False Informational 56 False Informational 57 False Informational 58 False Informational 59 False Informational 60 False Informational 61 False Informational 62 False Informational 63 False Informational 64 False Informational 65 False Informational 66 False Informational 67 False Informational 68 False Informational 69 False Informational 70 False Informational 71 False Informational 72 False Informational 73 False Informational 74 False Informational 75 False Informational 76 False Informational 77 False Informational 78 False Informational 79 False Informational 80 False Informational 81 False Informational 82 False Informational 83 False Informational 84 False Informational 85 False Informational 86 False Informational 87 False Informational 88 False Informational 89 False Informational 90 False Informational 91 False Informational 92 False Informational 93 False Informational 94 False Informational 95 False Informational 96 False Informational 97 False Informational 98 False Informational 99 False Informational 100 False Informational 101 False Informational 102 False Informational 103 False Informational 104 False Informational 105 False Informational 106 False Informational 107 False Informational 108 False Informational 109 False Informational 110 False Informational 111 False Informational 112 False Informational 113 False Informational 114 False Informational 115 False Informational 116 False Informational 117 False Informational 118 False Informational 119 False Informational 120 False Informational 121 False Informational 122 False Informational 123 False Informational 124 False Informational 125 False Informational 126 False Informational 127 False Informational Fixed Structure Length 0 (0x00000000) Big Hot Plug Count All Zeroes (256 x [0x0000]) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Sense Bus Parameters Peripheral Type 0x03 RMB 0x00 Versions 0x02 Misc 0x02 Additional Length 0x23 Support Bits 0x00 Vendor ID COMPAQ Product ID PROLIANT 6L2I Product Revision 0.10 Inquiry Valid 0x01 Installed Drive Map 0x00000180 Hot Plug Count All Zeroes (32 x [0x0000]) Physical Box 0 (0x00) Alarm Status 0x00 Temp Status 0x00 Valid Alarm Bits 0x00 Alarm Count 0 (0x0000) Specific Alarm Counts All Zeroes (8 x [0x0000]) Connection Flags 0x010a Position Connection Flag Status -------- -------------------------- ------------- 1 Internal Connector Is Used Informational 3 Proliant Storage Detected Informational SCSI Device Revision 0x01 Fan Status 0x00 More Inquiry Data 0x03 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 SCSI Device Type 0x00460e11 Bus Map 0x00003f80 Interrupt Count 0 (0x00000000) Ultra Bus Faults 0x00000000 SCSI Initiator ID 7 (0x07) SCSI Target ID 7 (0x07) Physical Port J2 Big Installed Drive Map 0x00 0x00 0x03 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Big Bus Map 0x00 0x00 0xff 0xff 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Big Box Map 0x00 0x00 0x3f 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Installed Box Map 0x01 More Connection Flags 0x01 Position Connection Flag Status -------- ------------------- ------------- 0 Running In Lvd Mode Informational 2 Using Id Numbering Informational Bay Count 0 (0x00) Expander Count 0 (0x00) Chassis Serial Number empty Fast Bus Faults 0x00000000 Ultra 2 Bus Faults 0x00000000 Ultra 3 Bus Faults 0x00000000 Ultra 320 Bus Faults 0x00000002 SEP Count 0 (0x00) SEP Device Types All Zeroes (16 x [0x00]) SEP Device Numbers All Zeroes (16 x [0x0000]) Expander Device Numbers All Zeroes (16 x [0x0000]) Offset To Extended Installed Drive Map 0 (0x0000) Offset To Extended Bus Map 0 (0x0000) Offset To Extended Box Map 0 (0x0000) Total Structure Length 0 (0x00000000) Offset To Element Type Modules 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) IO Module Present Map 0x00 Active IO Module Number 0x00 IO Module Failure Map 0x00 Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Zoned In Enclosure Bay Map All Zeroes (32 x [0x00]) Position Zoned In Enclosure Bay Status -------- ---------------------- ------------- 0 False Informational 1 False Informational 2 False Informational 3 False Informational 4 False Informational 5 False Informational 6 False Informational 7 False Informational 8 False Informational 9 False Informational 10 False Informational 11 False Informational 12 False Informational 13 False Informational 14 False Informational 15 False Informational 16 False Informational 17 False Informational 18 False Informational 19 False Informational 20 False Informational 21 False Informational 22 False Informational 23 False Informational 24 False Informational 25 False Informational 26 False Informational 27 False Informational 28 False Informational 29 False Informational 30 False Informational 31 False Informational 32 False Informational 33 False Informational 34 False Informational 35 False Informational 36 False Informational 37 False Informational 38 False Informational 39 False Informational 40 False Informational 41 False Informational 42 False Informational 43 False Informational 44 False Informational 45 False Informational 46 False Informational 47 False Informational 48 False Informational 49 False Informational 50 False Informational 51 False Informational 52 False Informational 53 False Informational 54 False Informational 55 False Informational 56 False Informational 57 False Informational 58 False Informational 59 False Informational 60 False Informational 61 False Informational 62 False Informational 63 False Informational 64 False Informational 65 False Informational 66 False Informational 67 False Informational 68 False Informational 69 False Informational 70 False Informational 71 False Informational 72 False Informational 73 False Informational 74 False Informational 75 False Informational 76 False Informational 77 False Informational 78 False Informational 79 False Informational 80 False Informational 81 False Informational 82 False Informational 83 False Informational 84 False Informational 85 False Informational 86 False Informational 87 False Informational 88 False Informational 89 False Informational 90 False Informational 91 False Informational 92 False Informational 93 False Informational 94 False Informational 95 False Informational 96 False Informational 97 False Informational 98 False Informational 99 False Informational 100 False Informational 101 False Informational 102 False Informational 103 False Informational 104 False Informational 105 False Informational 106 False Informational 107 False Informational 108 False Informational 109 False Informational 110 False Informational 111 False Informational 112 False Informational 113 False Informational 114 False Informational 115 False Informational 116 False Informational 117 False Informational 118 False Informational 119 False Informational 120 False Informational 121 False Informational 122 False Informational 123 False Informational 124 False Informational 125 False Informational 126 False Informational 127 False Informational Fixed Structure Length 0 (0x00000000) Big Hot Plug Count All Zeroes (256 x [0x0000]) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (72.8 GB Parallel SCSI) 2:0 : Physical Drive Status SCSI Bus 1 (0x01) SCSIID 0 (0x00) Block Size 512 Bytes Per Block (0x0200) Total Blocks 72.8 GB (0x087aa6c0) Reserved Blocks 0x00000440 Drive Model COMPAQ BD0728A4C4 Drive Serial Number 3KT4K52P00007643LVT8 Drive Firmware Revision HPB4 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason No Failure (0x00) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x07 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 1 QAS Is Enabled Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J2 Physical Box 0 (0x00) Physical Bay 0 (0x00) RPM 10000 RPM (0x00002731) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (72.8 GB Parallel SCSI) 2:0 : Monitor and Performance Statistics (Since Factory) Serial Number 3KT4K52P00007643LVT8 Firmware Revision HPB4 Product Revision COMPAQ BD0728A4C4 Reference Time 0x003b9558 Sectors Read 0x000000443cdd5f29 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000bac7e6e5e Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000000 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 2 : Drive Cage on Port J2 : Physical Drive (72.8 GB Parallel SCSI) 2:0 : Monitor and Performance Statistics (Since Reset) Serial Number 3KT4K52P00007643LVT8 Firmware Revision HPB4 Product Revision COMPAQ BD0728A4C4 Reference Time 0x0000006c Sectors Read 0x00000000000eabb1 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x000000000001a3b7 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs
HP COMPAQ 146Gb 15K
#046-034-005 1 шт на _Шереметьево-1 Сингапур2006
4.0
800 ₽
BF1468A4B3, no warnings, no errors
Комплектация: HDD HP BF1468A4B3 Салазки HP Spare 404712-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Thursday December 08, 2016 3:24:09PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 5 (0x05) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BF1468A4B3 Drive Serial Number JAXMJ05K Drive Firmware Revision HPB5 SCSI Inquiry Bits 0x3a Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 5 (0x05) RPM 15000 RPM (0x00003a98) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Factory) Serial Number JAXMJ05K Firmware Revision HPB5 Product Revision COMPAQ BF1468A4B3 Reference Time 0x002c4592 Sectors Read 0x00000033cb9e7b4e Read Errors Hard 0x000016cd Read Errors Retry Recovered 0x000000b9 Read Errors ECC Corrected 0x000000000000004d Sectors Written 0x0000000f02d28a63 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000002 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x003c Drive Rebuild Count 1 (0x0001) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Reset) Serial Number JAXMJ05K Firmware Revision HPB5 Product Revision COMPAQ BF1468A4B3 Reference Time 0x00000094 Sectors Read 0x0000000011173a89 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000000000219 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0x00a3 Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 15K
#046-034-006 1 шт на _Шереметьево-1 Сингапур2006
4.0
800 ₽
BF1468A4CC, no warnings, no errors
Комплектация: HDD HP BF1468A4CC Салазки HP Spare 404712-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Thursday December 08, 2016 3:24:09PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 3 (0x03) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BF1468A4CC Drive Serial Number 3KN2APLX00009708BSQP Drive Firmware Revision HPB5 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 3 (0x03) RPM 15000 RPM (0x00003aa7) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Factory) Serial Number 3KN2APLX00009708BSQP Firmware Revision HPB5 Product Revision COMPAQ BF1468A4CC Reference Time 0x0033ef17 Sectors Read 0x00000038cf82416f Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x000000115cb129c3 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Reset) Serial Number 3KN2APLX00009708BSQP Firmware Revision HPB5 Product Revision COMPAQ BF1468A4CC Reference Time 0x00000094 Sectors Read 0x00000000111738bd Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000000000634 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0x0088 Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 15K
#046-034-007 1 шт на _Шереметьево-1 Сингапур2006
4.0
800 ₽
BF1468A4BB, no warnings, no errors
Комплектация: HDD HP BF1468A4BB Салазки HP Spare 404712-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Thursday December 08, 2016 3:24:09PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 2 (0x02) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BF1468A4BB Drive Serial Number K80923GK Drive Firmware Revision HPB7 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 2 (0x02) RPM 15000 RPM (0x00003aa8) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Factory) Serial Number K80923GK Firmware Revision HPB7 Product Revision COMPAQ BF1468A4BB Reference Time 0x003c7604 Sectors Read 0x0000005a4dfdf596 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000016160520f2 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Reset) Serial Number K80923GK Firmware Revision HPB7 Product Revision COMPAQ BF1468A4BB Reference Time 0x00000094 Sectors Read 0x0000000011174024 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000000007f5 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0x00c0 Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 15K
#046-034-008 1 шт на _Шереметьево-1 Сингапур2006
4.0
800 ₽
BF1468A4CC, no warnings, no errors
Комплектация: HDD HP BF1468A4CC, P/N: 360209-011 Салазки HP Spare 404712-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Thursday December 08, 2016 6:44:20PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 2 (0x02) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BF1468A4CC Drive Serial Number 3KN1M6NW00007644FH69 Drive Firmware Revision HPB5 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x95 Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 2 (0x02) RPM 15000 RPM (0x00003aa7) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Factory) Serial Number 3KN1M6NW00007644FH69 Firmware Revision HPB5 Product Revision COMPAQ BF1468A4CC Reference Time 0x003c7625 Sectors Read 0x00000059f8551f11 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000016122f339a Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Reset) Serial Number 3KN1M6NW00007644FH69 Firmware Revision HPB5 Product Revision COMPAQ BF1468A4CC Reference Time 0x000000ad Sectors Read 0x0000000011173905 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x000000000000019c Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000000 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 15K
#046-034-009 1 шт на _Шереметьево-1 Сингапур2006
4.0
800 ₽
BF1468A4B3, no warnings, no errors
Комплектация: HDD HP BF1468A4B3, P/N: 321499-006 Салазки HP Spare 404712-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Thursday December 08, 2016 6:44:20PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 5 (0x05) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BF1468A4B3 Drive Serial Number JAX0XXVJ Drive Firmware Revision HPB5 SCSI Inquiry Bits 0x3a Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x95 Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 5 (0x05) RPM 15000 RPM (0x00003a98) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Factory) Serial Number JAX0XXVJ Firmware Revision HPB5 Product Revision COMPAQ BF1468A4B3 Reference Time 0x003abac7 Sectors Read 0x0000003f3d6b63ea Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000002740547f4 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Reset) Serial Number JAX0XXVJ Firmware Revision HPB5 Product Revision COMPAQ BF1468A4B3 Reference Time 0x000000ad Sectors Read 0x0000000012e07c07 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x000000000000019c Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000000 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 15K
#046-034-010 1 шт на _Шереметьево-1 Филипины2006
4.0
800 ₽
BF14689BC5, no warnings, no errors
Комплектация: HDD HP BF14689BC5, Part# : 365699-009 (CN: 29BC501CXSS01K) Салазки HP Spare 404712-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Friday December 09, 2016 10:22:30AM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 3 (0x03) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BF14689BC5 Drive Serial Number DN01P62011F90605 Drive Firmware Revision HPB1 SCSI Inquiry Bits 0x3a Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Timeout (0x07) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 3 (0x03) RPM 15000 RPM (0x00003a98) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Factory) Serial Number DN01P62011F90605 Firmware Revision HPB1 Product Revision COMPAQ BF14689BC5 Reference Time 0x0042bae2 Sectors Read 0x0000009c738126ba Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000012486bc437 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0024 Drive Rebuild Count 1 (0x0001) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Reset) Serial Number DN01P62011F90605 Firmware Revision HPB1 Product Revision COMPAQ BF14689BC5 Reference Time 0x00000047 Sectors Read 0x00000000111738bd Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000000000650 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0x00a2 Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 15K
#046-034-011 1 шт на _Шереметьево-1 Сингапур2006
4.0
800 ₽
BF1468A4CC, no warnings, no errors
Комплектация: HDD HP BF1468A4CC, P/N: 360209-011 (CT:2A4CC016CSE3XXJ) Салазки HP Spare 347779-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Friday December 09, 2016 10:22:30AM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 4 (0x04) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BF1468A4CC Drive Serial Number 3KN0R9EF00007618V85Z Drive Firmware Revision HPB5 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Plug Start Unit Failed (0x1c) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 4 (0x04) RPM 15000 RPM (0x00003aa7) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Factory) Serial Number 3KN0R9EF00007618V85Z Firmware Revision HPB5 Product Revision COMPAQ BF1468A4CC Reference Time 0x004005f3 Sectors Read 0x0000008bf9c37678 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000006 Sectors Written 0x00000011778acb74 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000002 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Reset) Serial Number 3KN0R9EF00007618V85Z Firmware Revision HPB5 Product Revision COMPAQ BF1468A4CC Reference Time 0x00000044 Sectors Read 0x0000000011173806 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000000000454 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0x00a3 Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 15K
#046-034-012 1 шт на _Шереметьево-1 Сингапур2006
4.0
800 ₽
BF1468A4B3, no warnings, no errors
Комплектация: HDD HP BF1468A4B3, P/N: 321499-006 (CT: 24AB3013ST40AB) Салазки HP Spare 404712-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Friday December 09, 2016 10:22:30AM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 5 (0x05) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BF1468A4B3 Drive Serial Number JAX3H36J Drive Firmware Revision HPB5 SCSI Inquiry Bits 0x3a Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 5 (0x05) RPM 15000 RPM (0x00003a98) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Factory) Serial Number JAX3H36J Firmware Revision HPB5 Product Revision COMPAQ BF1468A4B3 Reference Time 0x003aba5c Sectors Read 0x0000003f5ba4fa05 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x000000028292e125 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Reset) Serial Number JAX3H36J Firmware Revision HPB5 Product Revision COMPAQ BF1468A4B3 Reference Time 0x00000047 Sectors Read 0x000000001117381f Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000000002cd Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0x00aa Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 15K
#046-034-013 1 шт на _Шереметьево-1 Сингапур2006
4.0
800 ₽
BF1468A4BB, no warnings, no errors
Комплектация: HDD HP BF1468A4BB, P/N: 356914-009 (CT: 2A4BB01H1STOYG) Салазки HP Spare 404712-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Friday December 09, 2016 2:25:24PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 4 (0x04) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BF1468A4BB Drive Serial Number K805DY7K Drive Firmware Revision HPB9 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Plug Start Unit Failed (0x1c) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 4 (0x04) RPM 15000 RPM (0x00003aa8) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Factory) Serial Number K805DY7K Firmware Revision HPB4 Product Revision COMPAQ BF1468A4BB Reference Time 0x0042c976 Sectors Read 0x0000009c9d54bb91 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000007 Read Errors ECC Corrected 0x000000000000000d Sectors Written 0x0000001257df8759 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x00fa Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Reset) Serial Number K805DY7K Firmware Revision HPB9 Product Revision COMPAQ BF1468A4BB Reference Time 0x000000e5 Sectors Read 0x0000000011173e77 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000000000474 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000000 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 15K
#046-034-015 1 шт на _Шереметьево-1 Сингапур2006
4.0
800 ₽
BF14688286, no warnings, no errors
Комплектация: HDD HP BF14688286, P/N: 360209-005 (CT:28286016CRH9JJ) Салазки HP Spare ХХХХХ-ХХХ Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 2286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Friday December 09, 2016 3:48:25PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 5 (0x05) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BF14688286 Drive Serial Number 3KN055T3000075354RSJ Drive Firmware Revision HPB3 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Bus Reset Recovery Aborted (0x13) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 5 (0x05) RPM 15000 RPM (0x00003aa7) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Factory) Serial Number 3KN055T3000075354RSJ Firmware Revision HPB2 Product Revision COMPAQ BF14688286 Reference Time 0x0050f769 Sectors Read 0x000000aa729375fe Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000001bac358cf7 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000001 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Statistics (Since Reset) Serial Number 3KN055T3000075354RSJ Firmware Revision HPB3 Product Revision COMPAQ BF14688286 Reference Time 0x00000048 Sectors Read 0x0000000011173801 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000000001fc Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0x00ad Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:5 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 15K
#046-034-016 1 шт на _Шереметьево-1 Филипины2007
4.0
800 ₽
BF14689BC5, no warnings, no errors
Комплектация: HDD HP BF14689BC5, Part# : 365699-009 (CT: 29BC501CXVH01J) Салазки HP Spare 404712-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Friday December 09, 2016 3:48:25PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 4 (0x04) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BF14689BC5 Drive Serial Number DN01P7C08JAT0750 Drive Firmware Revision HPB1 SCSI Inquiry Bits 0x3a Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 4 (0x04) RPM 15000 RPM (0x00003a98) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Factory) Serial Number DN01P7C08JAT0750 Firmware Revision HPB1 Product Revision COMPAQ BF14689BC5 Reference Time 0x003663c0 Sectors Read 0x0000005b79afeaca Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000002 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000de234bc7a Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Reset) Serial Number DN01P7C08JAT0750 Firmware Revision HPB1 Product Revision COMPAQ BF14689BC5 Reference Time 0x00000049 Sectors Read 0x00000000111738a0 Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x00000000000003db Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0x0098 Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 15K
#046-034-017 1 шт на _Шереметьево-1 Филипины2007
4.0
800 ₽
BF14689BC5, no warnings, no errors
Комплектация: HDD HP BF14689BC5, Part# : 365699-009 (CT: 29BC501CXVG154) Салазки HP Spare 404712-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Friday December 09, 2016 5:31:39PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 3 (0x03) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BF14689BC5 Drive Serial Number DN01P7C08HWN0750 Drive Firmware Revision HPB1 SCSI Inquiry Bits 0x3a Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 3 (0x03) RPM 15000 RPM (0x00003a98) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Factory) Serial Number DN01P7C08HWN0750 Firmware Revision HPB1 Product Revision COMPAQ BF14689BC5 Reference Time 0x0026e3a1 Sectors Read 0x00000031c9ed840c Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x000000051033e919 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000004 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0003 Drive Rebuild Count 1 (0x0001) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Statistics (Since Reset) Serial Number DN01P7C08HWN0750 Firmware Revision HPB1 Product Revision COMPAQ BF14689BC5 Reference Time 0x0000005e Sectors Read 0x00000000111738bd Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000000000580 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0x009a Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:3 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 15K
#046-034-018 1 шт на _Шереметьево-1 Сингапур2006
4.0
800 ₽
BF14688286, no warnings, no errors
Комплектация: HDD HP BF14688286, P/N: 360209-005 (CT: 28286016CRHA0F) Салазки HP Spare 347779-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 734 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Friday December 09, 2016 5:31:39PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 2 (0x02) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BF14688286 Drive Serial Number 3KN05M4T00007536RW02 Drive Firmware Revision HPB3 SCSI Inquiry Bits 0x3e Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 2 (0x02) RPM 15000 RPM (0x00003aa7) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Factory) Serial Number 3KN05M4T00007536RW02 Firmware Revision HPB2 Product Revision COMPAQ BF14688286 Reference Time 0x0050f77f Sectors Read 0x000000ab25b62edb Read Errors Hard 0x0000001e Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000003 Sectors Written 0x0000001b7f098883 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0xffff Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Statistics (Since Reset) Serial Number 3KN05M4T00007536RW02 Firmware Revision HPB3 Product Revision COMPAQ BF14688286 Reference Time 0x0000005e Sectors Read 0x000000001117385a Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000000000742 Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000000 Seek Count 0x0000000000000000 Seek Errors 0x0000000000000000 Spin Cycles 0x00000001 Spin Up Time 0x00f1 Performance Test 1 0xffff Performance Test 2 0xffff Performance Test 3 0xffff Performance Test 4 0xffff Reallocation Sectors 0xffffffff Reallocated Sectors 0xffffffff DRQ Time Outs 0xffff Other Time Outs 0x0000 Drive Rebuild Count 0 (0x0000) Spin Retries 65535 (0xffff) Recovers Failed Read 0x0000 Recovers Failed Write 0x0000 Format Errors 0x0000 Self Test Failures 0xffff Not Ready Failures 0x00000000 Remap Abort Failures 0xffffffff IRQ Deglitch Count 4294967295 (0xffffffff) Bus Faults 0x00000000 Hot Plug Count 0 (0x00000000) Track Rewrite Errors 0xffff Write Errors After Remap 0xffff Background Firmware Revision 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Media Failures 0x0000 Hardware Errors 0x0000 Aborted Command Failures 0x0000 Spin Up Failures 0x0000 Bad Target Count 0 (0x0000) Predictive Failure Errors 0x00000000 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Violations Threshold Violation Flags All Zeroes (256 x [0x00]) Offset To Extended Threshold Violation Flags 0 (0x0000) Maximum Physical Devices Supported 0 (0x0000) Total Structure Length 0 (0x00000000) Fixed Structure Length 0 (0x00000000) Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:2 : Monitor and Performance Parameter Control Serial Number 0x8054 Firmware Revision 0x8248 Product Revision 0x8268 Reference Time 0x8184 Sectors Read 0x8108 Read Errors Hard 0x8184 Read Errors Retry Recovered 0x8184 Read Errors ECC Corrected 0x8188 Sectors Written 0x8108 Write Errors Hard 0x8184 Write Errors Retry Recovered 0x8184 Seek Count 33032 (0x8108) Seek Errors 0x8188 Spin Cycles 0x8184 Spin Up Time 0x8a82 Performance Test 1 0x0a82 Performance Test 2 0x8a82 Performance Test 3 0x8a82 Performance Test 4 0x8a82 Reallocation Sects 0x0a04 Reallocated Sects 0x8d84 DRQ Timeouts 0x0982 Other Timeouts 0x0182 Drive Rebuild Count 386 (0x0182) Spin Retries 2434 (0x0982) Recovers Failed Read 0x8182 Recovers Failed Write 0x0182 Format Errors 0x0182 Self Test Failures 0x0982 Not Ready Failures 0x0184 Remap Abort Failures 0x0984 IRQ Deglitch Count 0x0984 Bus Faults 33156 (0x8184) Hot Plug Count 0x0184 Track Rewrite Errors 0x0982 Write Errors After Remap 0x0982 Background Firmware Revision 0x0a48 Media Failures 0x0182 Hardware Errors 0x0182 Aborted Command Failures 0x0182 Spin Up Failures 0x0182 Bad Target Count 386 (0x0182) Predictive Failure Errors 0x2184
HP COMPAQ 146Gb 15K
#046-034-019 1 шт на _Шереметьево-1 Сингапур2006
4.0
800 ₽
BF1468B26B, no warnings, no errors
Комплектация: HDD HP BF1468B26B, P/N: 412751-015 (ST3146855LC) Салазки HP Spare 404712-001 Тест поверхности: Сектор начала тестирования: 0 Сектор конца тестирования: 286 374 239 Протестировано от общего объема в %: 100 Результаты сканирования: no warnings, no errors Подробнее смотри скриншот результатов проверки Victoria 4.47 --------- ADUReaport.txt --------- Time Generated: Friday December 09, 2016 5:31:39PM Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Physical Drive Status SCSI Bus 0 (0x00) SCSIID 4 (0x04) Block Size 512 Bytes Per Block (0x0200) Total Blocks 146.8 GB (0x11175330) Reserved Blocks 0x00000440 Drive Model COMPAQ BF1468B26B Drive Serial Number 3LN4YJB000009840SPFS Drive Firmware Revision HPB9 SCSI Inquiry Bits 0x32 Compaq Drive Stamped Stamped For Monitoring (0x01) Last Failure Reason Hot Removed (0x14) Device Flags 0xcd Position Device Flag Status -------- ----------------------------- ------------- 0 Drive Present And Operational Informational 2 Wide SCSI Transfers Enabled Informational 3 Synchronous Transfers Enabled Informational 6 Ultra SCSI Transfers Enabled Informational 7 Ultra2 SCSI Transfers Enabled Informational More Device Flags 0x25 Position Device Flag Status -------- ------------------------------------- ------------- 0 SMART Predictive Failure Supported Informational 2 SMART Predictive Failure Is Enabled Informational 4 Device Attached To Internal Connector Informational 5 Configured Data Drive Informational SCSI Lun 0x00 Yet More Device Flags 0x9d Position Device Flag Status -------- --------------------------------------- ------------- 0 DT Clocking Mode Informational 2 DT And ST Clocking Supported Informational 3 U320 Transfers Enabled Informational 4 Supports Packetized SCSI Informational 7 Drive Write Cache Setting Is Changeable Informational Even More Device Flags 0x05 Position Device Flag Status -------- ------------------------- ------------- 0 QAS Is Supported Informational 2 SCSI Arbitration Fairness Informational Spi Speed Rules 0xf8b70800 Physical Port J1 Physical Box 0 (0x00) Physical Bay 4 (0x04) RPM 15000 RPM (0x00003aa7) Device Type Parallel (0x00) SATA Version 0x00 Big Total Block Count 0x0000000000000000 RIS Starting LBA 0x0000000000000000 RIS Size 0 MB (0x00000000) WWID All Zeroes (20 x [0x00]) Controller PHY Map All Zeroes (32 x [0x00]) PHY Count 0 (0x0000) PHY Connected Device Type All Zeroes (256 x [0x00]) PHY To Drive Bay Number All Zeroes (256 x [0x00]) PHY To Attached Device Index All Zeroes (256 x [0x0000]) Box Index 0 (0x00) MSA Support 0x00 Extra Device Flags 0x0000 Negotiated Link Rate All Zeroes (256 x [0x00]) Phy To Phy Map All Zeroes (256 x [0x00]) Redundant Path Present Map 0x00 Redundant Path Failure Map 0x00 Active Path Number 0x00 Multi Path Port 1 empty Multi Path Port 2 empty Multi Path Port 3 empty Multi Path Port 4 empty Multi Path Port 5 empty Multi Path Port 6 empty Multi Path Port 7 empty Multi Path Port 8 empty Multi Path Box 1 0x00 Multi Path Box 2 0x00 Multi Path Box 3 0x00 Multi Path Box 4 0x00 Multi Path Box 5 0x00 Multi Path Box 6 0x00 Multi Path Box 7 0x00 Multi Path Box 8 0x00 Multi LUN Device LUN Count 0x00 Minimum Good Firmware Revision empty Vendor Unique Inquiry Bytes All Zeroes (20 x [0x00]) Current Temperature 0x00 Temperature Threshold 0x00 Maximum Temperature 0x00 Logical Blocks Per Physical Block 0x00 Current Q Depth Limit 0x0000 Switch Name All Zeroes (10 x [0x00]) Switch Port 0x0000 Alternate Paths Switch Name All Zeroes (40 x [0x00]) Alternate Paths Switch Port 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Power On Hours 0x0000 Percent Endurance Used 0x0000 Drive Authentication 0x00 Smart Carrier Authentication 0x00 Smart Carrier Application Version 0x00 Smart Carrier Bootloader Version 0x00 Smart Array 6i in Embedded Slot : Internal Drive Cage at Box 1 : Drive Cage on Port J1 : Physical Drive (146.8 GB Parallel SCSI) 1:4 : Monitor and Performance Statistics (Since Factory) Serial Number 3LN4YJB000009840SPFS Firmware Revision HPB9 Product Revision COMPAQ BF1468B26B Reference Time 0x0037d546 Sectors Read 0x0000005f3e65cace Read Errors Hard 0x00000000 Read Errors Retry Recovered 0x00000000 Read Errors ECC Corrected 0x0000000000000000 Sectors Written 0x0000000e6deb327f Write Errors Hard 0x00000000 Write Errors Retry Recovered 0x00000